MICROPROCESSOR PH SYSTEM 1010
MICROPROCESSOR PH SYSTEM 1010

MICROPROCESSOR PH SYSTEM 1010

MICROPROCESSOR PH SYSTEM 1010 Specification

  • Automation Grade
  • Automatic
  • Temperature Range
  • 0C to 100C
  • Voltage
  • 220 V AC
  • Feature
  • Highly Efficient
  • Frequency
  • 50 Hz
  • Power Source
  • AC Mains
  • Measurement Range
  • 0.00 to 14.00 pH
  • Accuracy
  • 100 %
  • Core Components
  • Microprocessor, Electrode, Power Supply
  • Model No
  • PH SYSTEM 1010
  • Capacity
  • Not Specified
  • Equipment Materials
  • Powder Coated Metal Cabinet
  • Type
  • Microprocessor Based pH System
  • Usage
  • Laboratory
  • Display Type
  • Digital LCD
  • Dimension (L*W*H)
  • Not Specified
  • Weight
  • Not Specified
  • Electrode Input
  • Glass Electrode, Reference Electrode
  • Storage
  • Non-Volatile Memory for Last Calibration
  • Resolution
  • 0.01 pH
  • Sample Size
  • Minimum 1 ml
  • Display Size
  • 16 x 2 Alpha Numeric LCD
  • Operating Humidity
  • Up to 90% RH
  • Response Time
  • <5 Seconds
  • Internal Battery Backup
  • Available (for Memory Retention)
  • Calibration
  • 3 Point Calibration
  • Input Voltage Range
  • 180-240V AC
 
 

About MICROPROCESSOR PH SYSTEM 1010

FEATURES

         Measure pH, mV & Temperature

         Highly Accurate & Easy to Operate

         Auto Temperature Compensation Facility

         7 Segment Bright Red LED Display

         Soft touch membrane keys

 

Microprocessor pH System 1010 is a solid state instrument designed to provide the precise pH, mV and temperature measurements. It has auto buffer recognition for 4.00, 7.00 and 9.2 pH buffers and auto 2 or 3 points buffer calibration. It has 7 segment bright red LED display. The instrument uses the latest microprocessor technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. The system has 6 soft touch membrane type keys for ease of operation. The calibration is retained even after the instrument is switched OFF

The instrument is extremely useful for agricultural and soil analysis laboratories, swimming pools, water quality control in boiler feed water, water works department, fertilizer plants, petroleum refineries, breweries, water purification plants etc.

 

SPECIFICATIONS : -

PARAMETERS

pH

mV

TEMPERATURE

Range

0 - 14.00 pH

0 - 1999

0 - 99.9 C

Resolution

0.01 pH

1 mV

0.1 C

Accuracy

 0.01,  1 Digit

1 mV,  1 Digit

0.1 C

Relative stability

0.02 pH/Hour

Acceptable Electrode Slope

80%% - 120%%

Temperature
Compensation

0 - 100 oC Auto/Manual

Temperature Sensor

Semi-Conductor (LM35) Type

Calibration

Auto (2 or 3 point)

Auto Buffer Recognition

4.00, 7.00 & 9.20 pH

Readout

7-Segment Bright Red LED display
(3 for Temperature and 4 for pH/mV)

Key Board

6 Keys, Soft Touch Membrane Type

Power supply

230V + 10%% AC, 50 Hz.

Accessories

Combination pH Electrode, Buffer Tablets (7.0 and 4.0 pH), Temperature Probe, Electrode Stand, Mains Lead,
 Operation Manual and Dust Cover

Note :  Specifications are subject to change due to continuous improvements.



Superior Accuracy and Efficiency

The PH SYSTEM 1010 ensures highly accurate pH measurements with an accuracy of 100%%. Advanced microprocessor technology, digital LCD display, and automatic operation contribute to its high efficiency. Its rapid response time of under five seconds and the 3-point calibration enhance precision and reliability, making it ideal for demanding laboratory environments.


User-Friendly Design and Features

Equipped with a 16 x 2 alpha-numeric LCD display and an intuitive interface, the PH SYSTEM 1010 offers easy operation and clear data presentation. The glass and reference electrode inputs allow for versatile usage, while a low minimum sample size of just 1 ml makes it suitable for a wide array of applications, even when sample availability is limited.


Robust Build and Reliable Performance

Constructed with a powder-coated metal cabinet, this system is built to withstand rigorous laboratory use. It includes an internal battery backup for memory retention and operates across a wide humidity (up to 90%% RH) and temperature range (0C to 100C), ensuring reliability in diverse conditions. The non-volatile memory safeguards calibration data, supporting consistent performance.

FAQs of MICROPROCESSOR PH SYSTEM 1010:


Q: How does the PH SYSTEM 1010 retain calibration data during power outages?

A: The PH SYSTEM 1010 is equipped with non-volatile memory and an internal battery backup. This ensures the last calibration settings are securely stored and retained, even in the event of a power interruption, allowing for uninterrupted and reliable measurements.

Q: What calibration process should be followed with this system?

A: This microprocessor-based pH system supports 3-point calibration, which should be performed using standard buffer solutions. Detailed instructions are provided in the manual, ensuring the instrument maintains high accuracy and precision during laboratory use.

Q: When should the pH system be recalibrated?

A: Recalibration is recommended after each electrode replacement, significant sample changes, or periodically based on your laboratorys protocol. Routine calibration ensures continued measurement accuracy and system performance.

Q: Where can the PH SYSTEM 1010 be utilized effectively?

A: Designed for laboratory environments across research, quality control, and educational sectors, the PH SYSTEM 1010 is suitable for use where precise pH measurement is required, including academic labs, industrial testing facilities, and research institutes.

Q: What are the benefits of using this microprocessor pH system?

A: Users benefit from rapid, highly accurate pH measurements, straightforward operation, and robust construction. Features like non-volatile memory, wide input voltage range, and sample versatility enhance laboratory workflow and analytical confidence.

Q: How much sample volume is required for a measurement?

A: Only a minimum of 1 ml sample is needed to perform reliable and accurate measurements, making the PH SYSTEM 1010 ideal for situations where sample volume is limited.

Q: What is the display specification, and how does it contribute to usability?

A: The system incorporates a large 16 x 2 alpha-numeric digital LCD display, providing clear and easy-to-read measurement data. This enhances user experience by simplifying the review of results and system messages during operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ANALYTICAL INSTRUMENTS Category

DIGITAL FLUOROMETER 681

DIGITAL FLUOROMETER 681

Measurement Range : Wide fluorescence intensity range (exact range unavailable)

Model No : 681

Core Components : Precise sensor display module electronic circuit

Accuracy : High accuracy for fluorescence measurement

Display Type : Digital display

Weight : Lightweight (exact weight unavailable)

AUTO KARL FISCHER TITRIMETER 751 & 761

AUTO KARL FISCHER TITRIMETER 751 & 761

Measurement Range : 10 g to 100 mg of water

Model No : 751 & 761

Core Components : Highprecision dosing system, electrochemical detector cell

Accuracy : 100 %

Display Type : Digital LCD Display

Weight : Approx. 6 kg

MICROPROCESSOR PH-EC-TDS METER  1615

MICROPROCESSOR PH-EC-TDS METER 1615

Measurement Range : pH: 014, EC: 0199.9 mS, TDS: 01999 ppm

Model No : 1615

Core Components : Sensor Probes, Microprocessor, Display Unit

Accuracy : 100 %

Display Type : LCD Digital Display

Weight : Approx. 3 kg

MICROPROCESSOR UV-VIS SPECTROPHOTOMETER 1371

MICROPROCESSOR UV-VIS SPECTROPHOTOMETER 1371

Measurement Range : 1901000 nm

Model No : 1371

Core Components : Microprocessor, Optical System

Accuracy : 100 %

Display Type : 16 x 2 Line Alphanumeric LCD Display

Weight : 13 kg



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038