MICROPROCESSOR FLAME PHOTOMETER 1381 Specification

  • Core Components
  • Microprocessor, Burner Assembly, Air Compressor, Nebulizer, Filters
  • Voltage
  • 220 V AC
  • Frequency
  • 50 Hz
  • Automation Grade
  • Automatic
  • Temperature Range
  • Ambient to required flame temperature
  • Model No
  • 1381
  • Accuracy
  • 100 %
  • Power Source
  • AC Mains
  • Capacity
  • 100 samples/hour
  • Feature
  • Highly Efficient
  • Equipment Materials
  • High-grade Stainless Steel and ABS Plastic
  • Type
  • Microprocessor Flame Photometer
  • Usage
  • Laboratory
  • Display Type
  • Digital LCD Display
  • Dimension (L*W*H)
  • 430 mm x 330 mm x 230 mm
  • Weight
  • 8.5 kg
  • Display Resolution
  • 0.1 ppm
  • Data Output
  • RS232 Serial Port for PC connectivity
  • Sample Aspiration
  • Automatic and Manual
  • Analogue Output
  • 02 V for recorder/plotter connectivity
  • Reading Hold Facility
  • Yes
  • Power Consumption
  • 60 W
  • User Interface
  • Membrane Touch Keys
  • Calibration
  • Automatic and Manual options
  • Safety
  • Flame Failure Protection System
  • Compressor
  • Built-in Oil-Free Air Compressor
  • Response Time
  • Less than 5 seconds
  • Ambient Operating Conditions
  • 10C to 40C, Maximum Relative Humidity 80%
  • Sample Volume
  • Minimum 3 ml
 
 

About MICROPROCESSOR FLAME PHOTOMETER 1381

FEATURES

Useful for Medical & Laboratory Use

Highly Accurate Using Micro controller

Direct Results in ppm and meq

3-Point Calibration Using Curve Fitting Software

Microprocessor Flame Photometer - 1381 is an ideal instrument for the determination of sodium, Potassium, Calcium and Lithium. It uses the latest micro controller technology and advanced engineering techniques so as to give enhanced and reproducibility. The System has 3-Point calibration facility using curve fitting software. It has soft touch membrane key for ease of operations.

The sample solution is aspirated through an automiser. Sample, Air and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the flame. The color of the flame is changed depending upon the concentration of elements present. Radiations from the flame passes through the sensing system and specific narrow band interference filter which permits only the characteristic radiation to pass to the photo-detector. The output of the photo-detector is then processed by the micro controller and the final results are displayed on the digital display.

SPECIFICATIONS : - 

 

ppm

meq/l

 

 

Serum

Urine

Range

Na: 0.1 - 100


K: 0.1 - 100


K: 15 - 100


Li: 0.5 - 100

Na: 0 - 200,
1: 100 dil

K: 0 - 10,
1: 100 dil

-


Li: 0 - 10,
1: 100 dil

Na: 0 - 250,
1: 100 dil

K: 0 - 100,
1: 100 dil

-


Li: 0 - 10,
1: 2 dil

Sensitivity

0.1 ppm

Accuracy

+ 1%% upto 40 ppm, + 2%% above 40 ppm

Readout

5 Digit 7-Segment Bright Red LED Display

Flame System

LPG & dry oil free air

Detector

Silicon Photodiode

Calibration

3-Point Calibration

Power

230 V + 10%% AC, 50 Hz

Dimensions

365 x 245 x 220 mm (L x B x H) (Approx.)

Weight

7.5 Kg (Approx.)

Air Supply

By oil free mini compressor unit with pressure regulator

Combustion Gas 

LPG controlled by precision regulator

Automiser

Axial flow type

Burner

Stainless steel

COMPRESSOR UNIT

Air Supply

By oil free mini compressor unit with pressure regulator

Combustion Gas

LPG controlled by precision regulator

Power

230 V + 10%% AC, 50 Hz

Dimensions

290 x 255 x 210 mm (L x B x H) (Approx.)

Weight

8 Kg (Approx.)

Note :  Specifications are subject to change due to continuous improvements.



Automatic and Manual Calibration

The 1381 model provides flexibility in calibration with both automatic and manual modes. This dual-functionality enables users to maintain accuracy while catering to specific application needs or preferences, ensuring continued reliability in various laboratory scenarios.


Safety Features for Reliable Operation

Equipped with a flame failure protection system, the photometer ensures operator safety and prevents sample loss or equipment damage. The use of high-grade stainless steel and ABS materials increases durability, while the oil-free compressor minimizes maintenance requirements.


User-Friendly Interface and Connectivity

This flame photometer features membrane touch keys for effortless control and navigation. With a digital LCD display for clear result visualization and RS232 serial port connectivity, users can easily manage data output for further analysis or record-keeping on connected PCs.

FAQs of MICROPROCESSOR FLAME PHOTOMETER 1381:


Q: How does the automatic calibration process work on the MICROPROCESSOR FLAME PHOTOMETER 1381?

A: The device automatically adjusts and sets baseline values through integrated microprocessor controls. This feature eliminates manual intervention, reduces errors, and ensures consistent accuracy for every measurement.

Q: What benefits does the flame failure protection system provide during operation?

A: The flame failure protection system monitors and quickly shuts off the flame in case of malfunction, preventing hazards and protecting both the operator and equipment from potential damage.

Q: When is the reading hold facility useful in laboratory workflows?

A: The reading hold facility is beneficial when users need to pause and securely record specific measurements for documentation, analysis or quality assurance without rushing the process.

Q: Where can data output from this photometer be connected?

A: Data can be exported directly to a personal computer using the RS232 serial port, and analogue output (02 V) is available for connectivity to recorders or plotters for extended data management.

Q: What is the recommended sample volume for accurate analysis?

A: The minimum sample volume required for precise measurements is 3 ml, ensuring sufficient material for reliable photometric assessment.

Q: How does the built-in oil-free air compressor benefit users?

A: The built-in oil-free air compressor provides a consistent air supply without the need for oil maintenance, resulting in reduced downtime and contamination, and supporting continuous, high-throughput sampling.

Q: What are the ambient operating conditions for the MICROPROCESSOR FLAME PHOTOMETER 1381?

A: The instrument operates effectively within a temperature range of 10C to 40C and maximum relative humidity of 80%%, allowing reliable performance across various laboratory environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ANALYTICAL INSTRUMENTS Category

DIGITAL TURBIDITY METER 335, 331 & 341

DIGITAL TURBIDITY METER 335, 331 & 341

Automation Grade : SemiAutomatic

Weight : 2.5 kg (approx.)

Dimension (L*W*H) : 245 x 205 x 100 mm

Core Components : Sensor, Digital Display, Calibration Standard

Feature : Highly Efficient

Equipment Materials : ABS Plastic Body

DIGITAL SALINITY METER 671

DIGITAL SALINITY METER 671

Automation Grade : Manual

Weight : 350 g

Dimension (L*W*H) : 200 x 70 x 35 mm

Core Components : Electronic Sensor, Microprocessor

Feature : Highly Efficient

Equipment Materials : ABS Plastic Body

HAEMOGLOBIN METER 1315

HAEMOGLOBIN METER 1315

Automation Grade : SemiAutomatic

Weight : 450 g

Dimension (L*W*H) : 210 mm x 140 mm x 60 mm

Core Components : Optical Sensor, Microprocessor

Feature : Highly Efficient

Equipment Materials : ABS Plastic

MICROPROCESSOR K.F. MOISTURE TITRATOR 1760

MICROPROCESSOR K.F. MOISTURE TITRATOR 1760

Automation Grade : SemiAutomatic

Weight : 7 kg (approx.)

Dimension (L*W*H) : 330 x 310 x 170 mm

Core Components : Microprocessor controller, magnetic stirrer, electrode, burette

Feature : Highly Efficient

Equipment Materials : Chemicalresistant ABS body and glass vessel



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038