MICROPROCESSOR EC-TDS-SAL METER 1602 Specification

  • Temperature Range
  • 0C to 100C
  • Voltage
  • 220 V 10%
  • Frequency
  • 50 Hz
  • Capacity
  • Can Process Multiple Tests Per Cycle
  • Feature
  • Highly Efficient
  • Core Components
  • Microprocessor, LCD Display, Probes
  • Automation Grade
  • Automatic
  • Accuracy
  • 100 %
  • Model No
  • 1602
  • Power Source
  • Electric
  • Equipment Materials
  • ABS Plastic Body
  • Type
  • Microprocessor EC-TDS-SAL Meter
  • Usage
  • Laboratory
  • Display Type
  • 16x2 Alphanumeric LCD Display
  • Dimension (L*W*H)
  • 245 mm x 195 mm x 65 mm
  • Weight
  • 2.5 kg
 
 

About MICROPROCESSOR EC-TDS-SAL METER 1602

FEATURES

·         16x2 Alphanumeric LCD Display

·         EC, TDS, Salinity & Temperature Measurements

·         Auto Temperature Compensation

·         Auto Ranging Facility

·         Programmable Ref. Temp & Temp. Coefficient

·         90 Samples Storage Facility

·         Printer Attachment Facility

 

Microprocessor Based EC-TDS-Sal Meter model 1602 is a solid state instrument designed for precise EC, TDS, Salinity and Temperature measurements. The instrument uses the latest microprocessor technology and advanced engineering techniques so as to give enchanced accuracy and reproducibility. The system has user friendly prompts, which guide you throughout the measurement process.

The instrument has 8 soft touch membrane type keys for ease of operation. It has the storage facility for 90 samples, which are retained in the memory even when the system is switched Off. Provision has also been made for attachment of any dot matrix printer with centronics interface so that any of the stored result can be printed.

The instrument is extremely useful for chemical & pharmaceutical inustry, agriculture and soil laboratories, swimming pools, water quality control in boiler feed water, water works department, fertilizer plants, petroleum refineries, breweries, water purification plants etc.

 

SPECIFICATIONS : -

PARAMETER

CONDUCTIVIITY

TDS

SALINITY

TEMPERATURE

Range Selection

Automatic

Automatic

Automatic

-

Range

0-20, 0-200uS, 0-2, 0-20,
0-200 mS

0-20, 0-200 ppm, 0-2,0-20,0-200
ppt

0-20, 0-200 ppm, 0-2,0-20,0-50
ppt

0-100oC

Accuracy

±0.5%% FS ±1 Digit

±1%% FS ±1 Digit

±1%% of Range, ±1 Digit

0.1oC

Resolution

0.01 uS

0.01 ppm

0.01 ppm

0.1oC

Cell constant

Adjustable 
(0.05-10.5)

Adjustable 
(0.05 -10.5)

Adjustable (0.05 -10.5)

-

Temperature 
compensation

Auto/Manual 
(0-100oC)

Auto/Manual (0-50oC)

Auto/Manual

-

Temperature 
Coefficient

-

Adjustable (0.1-4.0%%)

Adjustable (0.1-4.0%%)

-

Readout

16x2 Line Alphanumeric LCD with Backlit

Storage

Up to 90 Samples

Key board

8 soft touch membrane type keys

Printer Interface

Provision for attachment of Dot-Matrix Printer with Centronics Interface

Power

230V±10%%AC,50Hz

Dimensions 
(L x B x H)

Instrument: 285 x 190 x 90 mm (Approx.) 
Packing Box: 335 x 305 x 265 mm (Approx.)

Weight

2.5 Kg (Approx.)

Accessories

Conductivity/TDS Cell, Temperature Probe, Electrode Stand, Mains Lead, Dust Cover & Instruction Manual

Note :  Specifications are subject to change due to continuous improvements.




High Precision Laboratory Analysis

The EC-TDS-SAL Meter 1602 delivers consistently accurate readings for EC (0-200 mS/cm), TDS (0-1000 ppt), and Salinity (0-100 ppt). Its high-resolution digital output and automatic temperature compensation simplify complex laboratory analyses, making it an invaluable tool for research and quality control applications.


User-Friendly Features for Seamless Operation

With its intuitive soft-touch keypad and 16x2 alphanumeric LCD display, the meter is simple to operate. The built-in memory retains the last measured value, while RS232 interface connectivity streamlines data management and transfer to computers. Overload and error indicators provide clear operational guidance and safeguard against misuse.


Durable and Certified Construction

Housed in an ABS plastic body, this equipment is designed for durability and consistent performance. ISO 9001 certification underscores its adherence to stringent manufacturing standards, ensuring reliability for laboratories across various industries in India.

FAQs of MICROPROCESSOR EC-TDS-SAL METER 1602:


Q: How does the Microprocessor EC-TDS-SAL Meter 1602 help in laboratory measurements?

A: The meter provides highly accurate and efficient measurement of Electrical Conductivity, Total Dissolved Solids, and Salinity values essential for laboratory research and analyses. Its advanced microprocessor design, automatic temperature compensation, and multi-parameter capability streamline processes and minimize manual errors.

Q: What is the process for calibrating the EC-TDS-SAL Meter 1602?

A: Calibration is straightforwardusers can choose between automatic and manual options, following prompts via the soft-touch keypad and LCD display. The instrument guides you through the calibration steps, ensuring precision for every set of readings while enhancing repeatability.

Q: When should the calibration be performed on this instrument?

A: Calibration should be performed upon initial setup, after prolonged use, or whenever there is a noticeable drift in measurement accuracy. Regular calibration guarantees that the meter maintains reliable and valid results for all test samples.

Q: Where can I use the Microprocessor EC-TDS-SAL Meter 1602?

A: This meter is designed for laboratory environments, suitable for research institutions, quality control departments, water testing labs, and academic settings. Its sturdy ABS construction and adaptable humidity and temperature tolerances make it versatile for diverse indoor laboratory conditions.

Q: What benefits does the data retention and RS232 output provide?

A: The built-in memory stores the last measured value, enabling users to review recent data without repeating tests. The RS232 interface allows effortless connectivity to PCs, facilitating comprehensive data logging, sharing, and analysis for efficient record-keeping and reporting.

Q: How does the automatic temperature compensation feature enhance measurement accuracy?

A: Automatic temperature compensation ensures that EC, TDS, and SAL readings are not affected by fluctuations in sample temperature. This feature automatically adjusts readings, providing precise results over a wide temperature range from 0C to 100C.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ANALYTICAL INSTRUMENTS Category

MICROPROCESSOR DISSOLUTION TEST APPARATUS 1912

MICROPROCESSOR DISSOLUTION TEST APPARATUS 1912

Feature : Highly Efficient

Usage : Laboratory

Equipment Materials : Stainless Steel (SS 316 rods & paddles, SS 316 or USP Type I glass vessels)

Power Source : Electric (230V AC 10%, 50/60 Hz)

Model No : 1912

Automation Grade : Automatic

DIGITAL COLONY COUNTER 361, 362 & 363

DIGITAL COLONY COUNTER 361, 362 & 363

Feature : Highly Efficient

Usage : Laboratory

Equipment Materials : Robust body with smooth finish, durable plastic and metal

Power Source : Electric (230 V AC Mains)

Model No : 361, 362, 363

Automation Grade : Manual

MICROPROCESSOR DISSOLVED OXYGEN METER 1801

MICROPROCESSOR DISSOLVED OXYGEN METER 1801

Feature : Highly Efficient

Usage : Laboratory

Equipment Materials : ABS Plastic

Power Source : AC Mains

Model No : 1801

Automation Grade : Automatic

Slip & creep measurement apparatus

Slip & creep measurement apparatus

Feature : Highly Efficient

Usage : Laboratory

Equipment Materials : Stainless Steel, Mild Steel

Power Source : Electric

Model No : SCMA100

Automation Grade : Manual



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038