Back to top
   Call Me Free Send SMS Send Inquiry
Hand operated Vacuum pump
Hand operated Vacuum pump

Hand operated Vacuum pump

Hand operated Vacuum pump Specification

  • Automation Grade
  • Manual
  • Power Source
  • Hand operated (manual)
  • Model No
  • Standard Lab Series
  • Accuracy
  • 2%
  • Frequency
  • Manual Operation
  • Core Components
  • Vacuum pump body, piston, trigger handle, vacuum gauge, connecting hose
  • Temperature Range
  • Room temperature/ambient
  • Capacity
  • 0 to 550 mmHg (approximate) / 30 inHg
  • Type
  • Hand Operated Vacuum Pump
  • Usage
  • Laboratory vacuum generation, pressure/vacuum testing, fluid extraction
  • Dimension (L*W*H)
  • Approx. 200 x 50 x 140 mm
  • Handle Material
  • Ergonomic rubber for slip resistance
  • Maximum Suction
  • Up to 550 mmHg
  • Operation Pressure
  • Max atmospheric pressure differential
  • Hose Length
  • Approx. 60 cm supplied
  • Maintenance
  • Minimal, designed for easy cleaning
  • Finish
  • Nickel/Chrome plated to resist corrosion
 
 

About Hand operated Vacuum pump

 Hand operated Vacuum pump

Durable vacuum pump attain and hold vacuum of 25 inch of Hg.The pump has 15cc/stroke pumping rate and 7 psig positive pressure at the exhaust post.

Material: PVC

Packing

1


Exceptional Performance and Durability

Designed for sustained use in laboratory environments, this manual vacuum pump achieves up to 550 mmHg suction and incorporates robust nickel/chrome plating to resist corrosion. The ergonomic rubber handle ensures stable, slip-free operation even during extended procedures, while the minimal maintenance design supports long-term reliability and easy cleaning.


Precision and Versatility for Laboratory Tasks

The supplied 60 cm hose and integrated vacuum gauge provide flexibility and accurate monitoring across a range of laboratory applications. Whether performing vacuum generation, pressure testing, or fluid extraction, users benefit from dependable results due to the pumps 2% accuracy and straightforward manual operation.

FAQs of Hand operated Vacuum pump:


Q: How do I operate the Hand Operated Vacuum Pump?

A: To use the pump, firmly grip the ergonomic rubber handle and repeatedly squeeze the trigger to create suction. Connect the supplied 60 cm hose to your test setup, and observe the vacuum gauge for real-time measurement. The pump operates manually without the need for external power.

Q: What maintenance does the vacuum pump require?

A: This vacuum pump is designed for minimal maintenance. Simply wipe the nickel/chrome-plated surfaces with a damp cloth and ensure the hose and piston remain free from debris. Routine inspection helps maintain optimal performance and cleanliness.

Q: When is this pump suitable for laboratory use?

A: This hand-operated pump is ideal for laboratory environments requiring vacuum generation, pressure/vacuum testing, or fluid extraction at ambient room temperatures. It performs well whenever accurate, manually-driven vacuum control is necessary.

Q: Where can the vacuum pump be applied?

A: The pump is suitable for use in academic laboratories, research facilities, industrial quality control, and educational institutions throughout India where reliable manual vacuum generation is required.

Q: What process does the pump use to generate vacuum?

A: By manually operating the trigger, the internal piston lowers the pressure within the vacuum chamber, creating atmospheric pressure differential and achieving suction levels up to 550 mmHg. The vacuum gauge displays the current value throughout the process.

Q: What are the main benefits of using this hand-operated vacuum pump?

A: Users benefit from its ergonomic design for comfortable handling, durable construction for corrosion resistance, precise suction control, and easy cleaning. Its manual operation provides portability and utility without reliance on external power sources.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in NEW ADDITIONAL ITEMS Category

Spare Rotor

Spare Rotor

Temperature Range : Ambient conditions

Core Components : Rotor Motor

Usage : Laboratory centrifuge

Automation Grade : SemiAutomatic

Power Source : Electric

Display Type : LED Display

Midi Submarine Electrophoresis Unit

Midi Submarine Electrophoresis Unit

Temperature Range : Ambient conditions typically between 4C 50C

Core Components : Acrylic body electrodes

Usage : DNA/RNA gel electrophoresis analysis

Automation Grade : Manual

Power Source : External power supply

Display Type : None

Simplex Bottle Top Dispenser

Simplex Bottle Top Dispenser

Temperature Range : 15C to 40C

Core Components : Bottle Top Dispensing Mechanism

Usage : Laboratory liquid dispensing

Automation Grade : Manual

Power Source : Not required

Display Type : None

AUTO SECADOR Desiccator Cabinet

AUTO SECADOR Desiccator Cabinet

Temperature Range : Ambient to 60C

Core Components : Automatic Dehumidifier Unit, Sealing Door Gasket, Adjustable Shelves

Usage : Moisture Free Storage for Laboratory and Electronic Components

Automation Grade : Automatic

Power Source : 220V AC Mains

Display Type : Digital Display



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038