Back to top
Send SMS Send Inquiry
ROCKER Vacuum Pump
ROCKER Vacuum Pump

ROCKER Vacuum Pump

ROCKER Vacuum Pump Specification

  • Core Components
  • Diaphragm, Motor, Housing
  • Temperature Range
  • 5°C to 40°C
  • Power Source
  • Electric
  • Model No
  • Rocker 300
  • Capacity
  • 22 L/min
  • Automation Grade
  • Manual
  • Frequency
  • 50/60 Hz
  • Accuracy
  • ±2%
  • Voltage
  • 220 V
  • Usage
  • Laboratory vacuum filtration, general vacuum applications
  • Dimension (L*W*H)
  • 300 x 135 x 200 mm
  • Weight
  • Approx. 5 kg
  • Protection Class
  • IP 20
  • Pump Head Material
  • PTFE Coated
  • Tubing Connection
  • 8 mm hose barb
  • Motor Power
  • 1/8 HP (95 W)
  • Operation Mode
  • Continuous
  • Noise Level
  • < 50 dB
 
 

About ROCKER Vacuum Pump

ROCKER Vacuum Pump

Rocker is a piston powered and oil free vacuum pump.It contains a moisture trap/vacuum regulator.With light weight ROCKER is not only suitable for liquid filteration but also perfect for stack or ambient gas sampling


ModelPacking

Rocker 3001

Rocker 4001

Rocker 6001

Rocker 4101

Rocker 6101

Rocker 300 DC1
   
SpecificationRocker 300 220V / 50hzRocker 400 220V / 50hz
Max.Vaccum600 mmHg650 mmHg
200 mmHg3sec2sec
300 mmHg5sec3sec
400 mmHg8sec4sec
500 mmHg14sec6sec
600 mmHg25sec11sec
650 mmHg-18sec
Max. flowRate13L/Min23L/Min
Motor Rotation1400RPM1400RPM
Horse Power1/8 HP1/6 HP
Pole4P4P
Net Wt.4.1kg5.2kg
Port Thread1/8 PS1/8 PS
Noise Level54 db54 db
 
  • Compact, Light, Aluminium die cost construction.
  • Oil free, Piston Powered
  • Used for Liquid filteration for microbiology, suspended solid test, air sampling etc.


Quiet and Reliable Performance

Experience smooth operation at noise levels under 50 dB, suitable for environments where quiet equipment is desired. The ROCKER Vacuum Pump operates continuously and delivers consistent capacity for laboratory and general vacuum applications, ensuring minimal disruption during prolonged use.


Durable and Chemically Resistant

With a PTFE-coated pump head, the ROCKER 300 offers excellent resistance to corrosive chemicals commonly used in laboratories. The diaphragm mechanism enhances longevity, making it a trusted choice for professionals requiring sustained performance and chemical compatibility.


Versatile Laboratory Solutions

This vacuum pump accommodates various tasks, from filtration to general vacuum needs. Thanks to its manual automation, accurate performance (2%), and an 8 mm hose barb connection, it provides flexible usage for diverse laboratory settings and processes.

FAQs of ROCKER Vacuum Pump:


Q: How can the ROCKER Vacuum Pump be used in laboratory filtration processes?

A: The ROCKER Vacuum Pump is designed for continuous operation in laboratory filtration, providing a steady vacuum through its 8 mm hose barb connector. Its consistent 22 L/min capacity ensures efficient separation and filtration of samples in various research and analytical routines.

Q: What are the advantages of having a PTFE-coated pump head on the ROCKER 300?

A: A PTFE-coated pump head offers superior resistance against corrosive chemicals, safeguarding the pumps internal components and ensuring long-term durability, especially in laboratories that frequently handle aggressive reagents.

Q: When is continuous operation beneficial for vacuum pump usage?

A: Continuous operation is advantageous for processes requiring sustained vacuum over extended periods, such as prolonged filtrations, degassing, or sample preparation, minimizing downtime and supporting uninterrupted laboratory workflows.

Q: Where is the ROCKER Vacuum Pump typically installed or used?

A: This pump is commonly installed on laboratory benches or within research facilities across India, given its compact dimensions and lightweight design. It fits easily into laboratory setups needing reliable vacuum sources.

Q: What is the process for connecting the ROCKER Vacuum Pump to laboratory apparatus?

A: Connecting is straightforwardsimply attach compatible 8 mm tubing to the hose barb connection, secure the tubing to your filtration flask or apparatus, and plug the unit into a 220 V electrical outlet to begin operation.

Q: What are the benefits of the ROCKER 300s low noise level during laboratory work?

A: Its noise level under 50 dB contributes to a comfortable work environment, allowing users to concentrate on tasks without distraction, which is particularly beneficial in shared or quiet laboratory spaces.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in NEW ADDITIONAL ITEMS Category

SPINIT - Digital Magnetic Stirrer

SPINIT - Digital Magnetic Stirrer

Temperature Range : Ambient to 300°C

Core Components : Magnetic Stirrer Heating Plate

Usage : Laboratory Chemical Mixing

Model No : SPINITDS10

Feature : Temperature Control Variable Speed

Automation Grade : SemiAutomatic

Midi Submarine Electrophoresis Unit

Midi Submarine Electrophoresis Unit

Temperature Range : Ambient conditions typically between 4°C 50°C

Core Components : Acrylic body electrodes

Usage : DNA/RNA gel electrophoresis analysis

Model No : Midi Submarine Electrophoresis Unit

Feature : Compact and efficient for DNA/RNA separation

Automation Grade : Manual

Mini Secador with Gas Parts

Mini Secador with Gas Parts

Temperature Range : 25°C 80°C

Core Components : Gas Nozzle Drying Chamber

Usage : Laboratory Drying

Model No : MSGP100

Feature : Gas Drying System

Automation Grade : SemiAutomatic

Mini Submarine Electrophoresis Unit

Mini Submarine Electrophoresis Unit

Temperature Range : Ambient

Core Components : Electrodes Gel Tank Lid

Usage : DNA/RNA separation and analysis

Model No : MSU100

Feature : Compact design for smallscale electrophoresis

Automation Grade : Manual



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038