Back to top
Send SMS Send Inquiry
DIGITAL MELTING POINT APPARATUS 934 & 935
DIGITAL MELTING POINT APPARATUS 934 & 935

DIGITAL MELTING POINT APPARATUS 934 & 935

DIGITAL MELTING POINT APPARATUS 934 & 935 Specification

  • Frequency
  • 50 Hz
  • Measurement Range
  • 30°C to 300°C (Melting Point Range)
  • Feature
  • Highly Efficient
  • Temperature Range
  • Ambient to 300°C
  • Model No
  • 934 / 935
  • Automation Grade
  • Semi-automatic
  • Accuracy
  • 100 %
  • Capacity
  • 3 capillaries
  • Core Components
  • Heating chamber, digital display, capillary holder, magnifying lens
  • Power Source
  • Electric
  • Voltage
  • 230 V AC
  • Equipment Materials
  • Powder-coated metal body
  • Type
  • Digital Melting Point Apparatus
  • Usage
  • Laboratory
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 300 x 220 x 165 mm
  • Weight
  • Approx. 5 kg
  • Heating Rate
  • 1C/min to 10C/min adjustable
  • Cooling
  • Manual cooling option
  • Controller
  • Microprocessor based temperature controller
  • Alarm
  • Audio alarm at set melting point
  • Melting Point Indication
  • Both digital and light indication
  • Capillary Diameter
  • 1.4 mm (standard capillaries)
  • Power Consumption
  • Approximately 250 W
  • Fusing
  • Built-in fuse for overload protection
  • Construction
  • Corrosion-resistant, durable finish
  • Observation System
  • Built-in magnifying lens with clear viewing window
  • Safety
  • Over-temperature protection
 
 

About DIGITAL MELTING POINT APPARATUS 934 & 935

FEATURES

         Extremely Useful for Pharmaceutical Industry

         Highly Accurate & Easy to Operate

         4 Digit 7-Segment LED Display

         Digital Readout for Temperature 0.1 C (Model - 935) and 1 C (Model - 934)

         Silicon Oil-Bath and In-built Magnetic Stirrer for Uniform Heating

         Glare-free Illuminator and Large Magnifier for Stainfree Observation

 

Melting Point Apparatus with 4 digit, 7-Segment LED display is designed for accurate measurement of melting points and for checking the melting range of the solid samples. The apparatus consists of a silicon bath of about 200 ml capacity, covered with Ptfe cover with 3 holes fitted, with a special type of oil immersion heater having three holes for holding the capillaries, one for boiling point tube and one for the thermometer. The apparatus consists of in-built magnetic stirrer, an electronic controller with indicator for precisely adjusting the rate of heating of silicon oil-bath, an ON/OFF switch, a pilot lamp, with magnifier, a glare free background illuminator, a High/Low range temperature selector switch and digital temperature indicator with PT100 RTD sensor

The 'Start' switch is used to start the measurement of melting point. User can sto the measurement using the 'Stop' switch after the instrument reaches the melting point of the sample. The display will always show the last temperature where 'Stop' switch pressed in the last measurement. Clear switch is used to clear the display to zero.

 

SPECIFICATIONS : -

Display

4 Digit, 7-Segment LED Display (Model - 935)
3 Digit, 7-Segment LED Display (Model - 934)

Temperature

0 - 300 C

Resolution

0.1 C (Model - 935)
1 C (Model - 934)

Capillary Glass Tubes

12 mm long, 0.8 - 1.1 mm internal diameter

Boiling Point  Glass Tubes

75 mm long glass tube

Sample Amount

Fine powder properly dried at a temperature considerably below its melting point 4 - 6 mm high

Oil-Bath

Silicon oil-bath beaker 200 ml capacity with Ptfe cover fitted with oil immersion heater. It has three holes for holding the capillaries, boiling point tube and thermometer

Stirrer Speed

Controllable with front knob

Power

230 V 10%%, 50 Hz. AC

Dimensions

315 x 290 x 230 mm (L x B x H) (Approx.)

Weight

12 Kg (Approx.)

Accessories

Box of Capillaries, Boiling Point Tubes - 2 Set, Thermometer with Range 0 - 360 C, Magnetic Capsule, Bottle of Silicon Oil, Glass Cylindrical Beaker with Ptfe cover for beaker fitted with immersion heater, Operation Manual, Dust Cover

Note :  Specifications are subject to change due to continuous improvements.



Reliable Melting Point Determination

The DIGITAL MELTING POINT APPARATUS 934 & 935 ensures highly accurate detection of melting points with a microprocessor-based temperature controller, accommodating a wide measurement range from 30C to 300C. Its built-in magnifying lens and viewing window provide clear sample observation, while the corrosion-resistant body delivers durability for long-term use in various laboratory environments.


User-friendly and Efficient Operation

Designed for laboratory professionals, these semi-automatic models allow adjustment of heating rate from 1C/min to 10C/min, supporting efficient testing protocols. Up to three samples can be examined simultaneously, with both digital and light indication of melting point, audio alarm at set point, and manual cooling, streamlining workflow and improving efficiency.


Comprehensive Safety Features

Over-temperature protection, built-in fuse for overload scenarios, and a durable powder-coated finish make these apparatuses safe and low-maintenance. The display is fully digital for precise readings, ensuring data accuracy and reducing risk of user error, while the audio alarm and intuitive interface promote safe, convenient operation in busy labs.

FAQs of DIGITAL MELTING POINT APPARATUS 934 & 935:


Q: How does the DIGITAL MELTING POINT APPARATUS 934 & 935 ensure accuracy during measurements?

A: These models utilize a microprocessor-based temperature controller and a digital display that allow precise setting and monitoring of temperature. The built-in magnifying lens and clear viewing window provide detailed observation of samples. Together, these features ensure 100%% accuracy when determining melting points.

Q: What is the process for determining the melting point with these apparatuses?

A: Simply insert up to three capillaries filled with your sample into the holder, set your desired heating rate (between 1C/min and 10C/min), and observe through the magnifying lens as the temperature rises. When the substance melts, both digital and light indicators will trigger, accompanied by an audio alarm.

Q: When is manual cooling required, and how is it done?

A: Manual cooling is required after completing a melting point determination, particularly when the chamber temperature is high and a new set of samples needs to be introduced. Wait for the chamber to cool naturally, or expedite cooling using the manual cooling system as directed in the user manual.

Q: Where can this apparatus be used most effectively?

A: The DIGITAL MELTING POINT APPARATUS 934 & 935 is ideal for laboratory environments in educational, pharmaceutical, or research settings across India, where precise and reliable melting point analysis of substances is essential.

Q: What are the main benefits of using this melting point apparatus?

A: Key benefits include high efficiency, the ability to test three samples simultaneously, a fully digital and audio indication system, superior accuracy, durable corrosion-resistant construction, and comprehensive built-in safety features for worry-free operation.

Q: How does the apparatus enhance laboratory workflows?

A: By accommodating multiple samples at once, providing rapid heating rate adjustment, and offering both digital and light indicators along with audio alarms, these models accelerate routine analyses and reduce supervision time, making laboratory workflows more productive.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ANALYTICAL INSTRUMENTS Category

DISSOLVED OXYGEN METER 801 & 811

DISSOLVED OXYGEN METER 801 & 811

Core Components : Sensor Probe, Processor Unit, Display Screen

Capacity : Standard

Weight : 600g

Power Source : Battery Operated

Type : Portable Dissolved Oxygen Meter

Accuracy : 100 %

DOUBLE BEAM UV-VIS SPECTROPHOTOMETER 2375

DOUBLE BEAM UV-VIS SPECTROPHOTOMETER 2375

Core Components : Light Source, Detector, Monochromator, Microprocessor System

Capacity : 1 cm path length cuvette

Weight : 18 kg

Power Source : Electric

Type : Double Beam UVVIS Spectrophotometer

Accuracy : 100 %

MICROPROCESSOR K.F. MOISTURE TITRATOR 1760

MICROPROCESSOR K.F. MOISTURE TITRATOR 1760

Core Components : Microprocessor controller, magnetic stirrer, electrode, burette

Capacity : 10 g 100 mg (typical)

Weight : 7 kg (approx.)

Power Source : AC Mains

Type : Microprocessorbased K.F. Moisture Titrator

Accuracy : 100 %

DIGITAL PH, CONDUCTIVITY & TEMPERATURE METER 181

DIGITAL PH, CONDUCTIVITY & TEMPERATURE METER 181

Core Components : Electrode Probe, Main Unit, Display Panel

Capacity : Multiparameter (pH, Conductivity & Temperature)

Weight : Approx. 1 kg

Power Source : 230V AC

Type : Benchtop Meter

Accuracy : 100 %



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038