Rotary Vacuum Evaporator Cold Trap Condenser Model No. SSI/68 Specification

  • Temperature Range
  • -40C to +100C
  • Frequency
  • 50 Hz
  • Automation Grade
  • Manual
  • Feature
  • Highly Efficient
  • Power Source
  • Electrical
  • Voltage
  • 220 V AC
  • Capacity
  • 1 to 2 Liters
  • Model No
  • SSI/68
  • Accuracy
  • 100 %
  • Measurement Range
  • Suitable for volatile solvent recovery
  • Core Components
  • Cold Trap Condenser, Vacuum Pump Connection, Glass Trap Flask
  • Equipment Materials
  • Borosilicate Glass, SS304 Stainless Steel
  • Type
  • Rotary Vacuum Evaporator Cold Trap Condenser
  • Usage
  • Laboratory
  • Dimension (L*W*H)
  • 45 cm x 30 cm x 35 cm
  • Weight
  • 15 kg (approx.)
 
 

About Rotary Vacuum Evaporator Cold Trap Condenser Model No. SSI/68

Rotary Vacuum Evaporator Cold Trap Condenser Model No. SSI/68

This model of evaporator is supplied complete with geared drive non sparking noiseless motor offering smooth, speed control by analog knob upto 200RPM, jack arrangement is fitted on tapered front base for positioning glass assembly. Double walled water bath thermostatic temperature controller  glass condenser double walled with one opening for vacuum and top reservoir for cooling medium, pear (Kjeldhal) shaped evaporating falsk capacity 800ml, receiver flask capacity one litre fitted with a ball joint, feeding tube, vapour path tube provided with a pressure tube,  seal, clips and spring a complete working unit.


Replacement part for (Cold Trap Condenser) SSI/68

 

SSI/68/01 Cold Trap Condenser double walled with S-35 ball at bottom for connecting to receiving flask, with one opening for vacuum & top reservoir for cooling medium cock for feeding on one side while the other side sill be connected to motor with ring.
SSI/68/02 Vapour path tube B-24, B-29
SSI/68/03 Gasket seal for vapour tube (VITON)
SSI/68/04 Gasket seal for special chemicals
SSI/68/05 Feed tube for condenser without PTFE pipe
SSI/68/06 Receiving flask with S-35 cup (socket) joint capacity 1000ml
SSI/68/07 Evaporating flask kjeldhal cap. 800ml B-24
SSI/68/08 Evaporating flask kjeldhal cap. 500ml B-24
SSI/68/09 Evaporating flask kjeldhal cap. 300ml B-24
SSI/68/10 Evaporating flask kjeldhal cap. 100ml B-24
SSI/68/11 Tension spring to hold condenser
SSI/68/12 Wire clip
SSI/68/13 Ball joint clip with screw lock
SSI/68/14 Water bath double walled SS with thermostatic temperature controller
SSI/68/15 Spare heater for water bath (ISI Mark)
SSI/68/16 Suitable oil free vacuum pump for rotary evaporator with vacuum gauge & regulator 
SSI/68/17 Glass safety trap


Superior Solvent Recovery and Protection

The SSI/68 Rotary Vacuum Evaporator Cold Trap Condenser enables efficient recovery of volatile solvents and minimizes their passage to the vacuum pump, significantly prolonging equipment lifespan. Its borosilicate glass coil and spherical trap flask assure excellent performance and chemical compatibility, while reliable temperature monitoring allows secure and optimal operation. The cold traps advanced vacuum sealing ensures loss-free operation during solvent collection.


Versatile Cooling Options for Maximum Efficiency

Designed for laboratories requiring adaptable performance, this unit accommodates both ice cooling and circulating chillers. This flexibility enables users to tailor the traps cooling efficiency to their specific applications, further enhancing solvent recovery rates and system safety. The devices robust stainless steel finish ensures long-term durability and ease of cleaning, making it an asset for routine or demanding experimental work.

FAQs of Rotary Vacuum Evaporator Cold Trap Condenser Model No. SSI/68:


Q: How does the SSI/68 cold trap condenser protect the vacuum pump during operation?

A: The Model SSI/68 enhances the longevity of vacuum pumps by condensing and collecting volatile solvent vapors in its spherical glass trap, preventing those vapors from reaching and potentially damaging the pump.

Q: What installation process should be followed for setting up the cold trap condenser?

A: Begin by placing the unit securely on a benchtop, connect the 12 mm tubing to the vacuum pump and glass trap flask, and attach the cooling systemeither ice or a compatible circulating chiller. Ensure all PTFE seals are properly fitted for vacuum integrity, and check the temperature indicator before operation.

Q: When should I use the circulating chiller instead of just ice as the traps cooling system?

A: Use a circulating chiller when a stable, lower temperature is required (especially near or below -40C) or during prolonged operation, as chillers provide consistent cooling compared to ice, which may need regular replenishment.

Q: Where is the condenser most effectively utilized in a laboratory setting?

A: This rotary vacuum evaporator cold trap is best suited for locations where solvent recovery and vacuum pump protection are critical, such as in analytical, chemical synthesis, or pharmaceutical laboratories.

Q: What are the key benefits of using a glass spherical trap flask and borosilicate condensing coil in this model?

A: The glass spherical trap flask offers increased surface area for vapor condensation, and the borosilicate condensing coil ensures high resistance to thermal shock and chemical corrosion, providing durable, contamination-free operation.

Q: How do I monitor and maintain safe operation of the equipment?

A: Monitor the built-in temperature indicator regularly, check vacuum seals before use, and ensure overload-protected electricals are functioning properly. Routine cleaning of the glass trap and condensing coil after use will maintain performance and safety.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in SCIENTIFIC & LABORATORY RESEARCH APPARATUS Category

Incubator shaker

Incubator shaker

Usage : Laboratories Research Centers

Feature : Temperature Control Shaking Function

Capacity : 1015 flasks

Accuracy : 1C

Automation Grade : SemiAutomatic

Equipment Materials : Stainless Steel Glass

B.o.d. Incubator

B.o.d. Incubator

Usage : Laboratory

Feature : Highly Efficient

Capacity : 250 L

Accuracy : 100 %

Automation Grade : Automatic

Equipment Materials : Stainless Steel Inner Chamber, Powder Coated Outer Body

Chiller Refrigerated Circulater Model No. SSI/71

Chiller Refrigerated Circulater Model No. SSI/71

Usage : Laboratory

Feature : Highly Efficient

Capacity : 4.5 Liters

Accuracy : 100 %

Automation Grade : SemiAutomatic

Equipment Materials : Corrosion resistant Stainless Steel

Rotary Vacuum Evaporator Diagonal Condenser Model No. SSI/62

Rotary Vacuum Evaporator Diagonal Condenser Model No. SSI/62

Usage : Laboratory

Feature : Highly Efficient

Capacity : 1 Litre

Accuracy : 100 %

Automation Grade : SemiAutomatic

Equipment Materials : Borosilicate Glass and Stainless Steel