Back to top
Send SMS Send Inquiry
AUTO KARL FISCHER TITRIMETER 751 & 761
AUTO KARL FISCHER TITRIMETER 751 & 761

AUTO KARL FISCHER TITRIMETER 751 & 761

AUTO KARL FISCHER TITRIMETER 751 & 761 Specification

  • Power Source
  • AC Mains
  • Measurement Range
  • 10 g to 100 mg of water
  • Voltage
  • 230V
  • Frequency
  • 50 Hz
  • Model No
  • 751 & 761
  • Temperature Range
  • 5C to 40C
  • Core Components
  • High-precision dosing system, electrochemical detector cell
  • Accuracy
  • 100 %
  • Automation Grade
  • Automatic
  • Capacity
  • 10 g to 100 mg HO
  • Feature
  • Highly Efficient
  • Equipment Materials
  • Sturdy chemical-resistant body, glass titration vessel
  • Type
  • Automatic Karl Fischer Titrimeter
  • Usage
  • Laboratory
  • Display Type
  • Digital LCD Display
  • Dimension (L*W*H)
  • 345 mm x 310 mm x 165 mm
  • Weight
  • Approx. 6 kg
  • Stirrer Type
  • Magnetic PTFE coated stirrer
  • Sample Type
  • Liquid and Solid
  • Power Consumption
  • Approx. 40 W
  • Titration Method
  • Volumetric Karl Fischer
  • Burette Volume
  • 10 ml
  • Operating Humidity
  • Max 80% RH
  • Printer Interface
  • Built-in thermal printer support
  • Safety Feature
  • Overload and leakage current protection
  • Output Ports
  • RS232 port for data transfer
  • Alarm System
  • Automated end-point alarm
  • Glassware Included
  • 250 ml reservoir, titration vessel, burette
  • Compliance
  • ISO/GLP standards
  • Memory Storage
  • Up to 100 test results
  • End Point Detection
  • Electrochemical Bivoltametric
  • LCD Display Size
  • 16x2 alphanumeric
  • User Interface
  • Soft-touch membrane keypad
  • Calibration
  • Automatic and Manual
  • Additional product specifications
 
 

About AUTO KARL FISCHER TITRIMETER 751 & 761

FEATURES

         Auto Titration Control

         Separate Control & Titration Units

         Auto Zero Burette

         Adjustable Timer

         Visual & Audible Alarm

 

Auto Karl Fischer Titrimeter 761 is an automatic apparatus designed to carry out Karl Fischer Titrations for accurate determination of moisture content in various samples. The instrument comprises of two units i.e CONTOL UNIT & TITRATION UNIT. The CONTROL UNIT controls the complete automatic titration. On pressing the START button, the titration starts and the KF reagent is added automatically from the burette, through a solenoid valve into the titration vessel. As soon as the end point is reached, the titration is stopped automatically by the Control Unit. It has fully solid state circuitry incorporating advanced IC technology.

Titration unit contains the magnetic stirring mechanism and the solenoid valve assembly. The cabinet is designed to serve as a titration stand.

Karl Fischer method for determination of moisture content is used in pharmaceutical and drug manufacturing industries, food stuff, sugar, wood, paper and textile industries, petroleum refineries, chemical and fertilizer units etc.

 

SPECIFICATIONS : -

CONTROL UNIT

Display

Array of 10 LEDs

Timer

Adjustable Timer

Buzzer

Yes

Sample Size

1-50 mg of Water

K.F.Dispensing Resolution

0.05 ml.

Measuring Electrode

Dual Platinum

Indications

RUN}

 

ADD } Display in Auto Mode

 

END}

Detection

Current sensing by electronic control

Dimensions

L340 X B250 X H125 mm. (Approx.)

Weight

2 kg. (Approx.)

TITRATION UNIT

Titration Cell

Air Tight 200ml.

Stirrer

Variable speed magnetic stirrer with On/Off control

K.F.Flow

Automatic Sensitive Control Valve for KF Reagent

Burette

Pressure filling auto zero burette with 0.05 ml resolution

Power

230V???10%% 50Hz, AC

Dimensions

L325 X B180 X H98 mm (Approx.)

Weight

3 Kg. (Approx.)

Accessories

  Burette (Clear Glass) 10 ml * Reservoir Bottle 500 ml

  Moisture trap with rubber bellow for air pumping

  Titration Cell

  Dual Platinum Electrode

  Solenoid Valve Assembly

  Magnetic Capsule

  Set of 2 Clamps

  Rubber Tubing

  Nozzle

  Instruction Manual

Note :  Specifications are subject to change due to continuous improvements.



Advanced Titration for Ultimate Precision

AUTO KARL FISCHER TITRIMETER 751 & 761 harness the renowned volumetric Karl Fischer method, enhanced by an electrochemical bivoltametric end-point detector. This ensures unmatched measurement accuracy for water content from as low as 10 g up to 100 mg. Designed to support rigorous laboratory workflows, reliability and reproducibility are assured with every test.


Effortless Operation and Data Management

The models 751 & 761 prioritize user experienceoffering a soft-touch membrane keypad, 16x2 alphanumeric digital LCD display, and built-in thermal printer for instant data output. Users can store up to 100 test results in memory, while data transfer is streamlined via the RS232 portsupporting contemporary documentation requirements in laboratory environments.


Safety, Durability, and Compliance at the Core

Engineered for longevity, the titrimeter features a chemically resistant body and glassware, overload and leakage current protection, and an automated endpoint alarm. Compliant with ISO/GLP standards, it provides users peace of mind with every operation, emphasizing safe and standardized laboratory practices.

FAQs of AUTO KARL FISCHER TITRIMETER 751 & 761:


Q: How does the AUTO KARL FISCHER TITRIMETER 751 & 761 determine the water content in samples?

A: The titrimeter uses the volumetric Karl Fischer titration method enhanced with an electrochemical bivoltametric technique for precise end-point detection. This process accurately quantifies water in both liquid and solid samples, ensuring reliable lab results.

Q: What types of samples can be analyzed with these models?

A: Both models are designed to test water content in a wide range of liquid and solid samples. With a measured capacity of 10 g to 100 mg HO, they cater to diverse laboratory analysis requirements.

Q: Where is this equipment best utilized?

A: The AUTO KARL FISCHER TITRIMETER 751 & 761 are intended for laboratory environments, making them suitable for quality control, research and development, and other analytical applications in industries such as pharmaceuticals, chemicals, food, and more.

Q: What is the procedure for starting a titration with these devices?

A: Users simply prepare the sample, insert it into the titration vessel, and follow prompts on the digital LCD using the membrane keypad. An automatic or manual calibration can be selected, and the titrimeter then performs the analysis, signaling the end-point with an automated alarm.

Q: How is data managed and outputted on these titrimeters?

A: Up to 100 test results can be stored internally. For documentation, results can be printed via the integrated thermal printer or transferred digitally using the RS232 output port, facilitating efficient data management.

Q: What safety and compliance features are included in these models?

A: The equipment features overload and leakage current protection, an automated endpoint alarm, and is constructed from chemical-resistant materials. Both 751 & 761 comply with ISO and GLP standards, ensuring operational safety and standardization.

Q: What are the main benefits of using the AUTO KARL FISCHER TITRIMETER 751 & 761 in a laboratory?

A: Users benefit from high measurement accuracy, easy operation, robust safety, and quick data output. These features collectively improve laboratory efficiency, data reliability, and safety for a wide range of analytical tasks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ANALYTICAL INSTRUMENTS Category

MICROPROCESSOR PHOTO COLORIMETER 1312

MICROPROCESSOR PHOTO COLORIMETER 1312

Power Source : 230V AC 10%, 50 Hz

Measurement Range : 400700 nm

Voltage : 230V AC

Temperature Range : 0C 50C

Frequency : 50 Hz

Equipment Materials : ABS Plastic Body

MICROPROCESSOR SPECTROPHOTOMETER 1305

MICROPROCESSOR SPECTROPHOTOMETER 1305

Power Source : Electric

Measurement Range : 340 nm to 960 nm

Voltage : 230 V AC

Temperature Range : 0C to 50C

Frequency : 50 Hz

Equipment Materials : ABS Plastic Body

MICROPROCESSOR UV-VIS SPECTROPHOTOMETER 1371

MICROPROCESSOR UV-VIS SPECTROPHOTOMETER 1371

Power Source : Electric

Measurement Range : 1901000 nm

Voltage : 230 V AC 10%, 50 Hz

Temperature Range : 0100 C

Frequency : 50 Hz

Equipment Materials : ABS Plastic

MICROPROCESSOR PH-EC METER 1611

MICROPROCESSOR PH-EC METER 1611

Power Source : AC Mains (220V 10%, 50 Hz)

Measurement Range : pH 014, EC 0200 mS/cm

Voltage : 220V AC

Temperature Range : 0C to 100C

Frequency : 50 Hz

Equipment Materials : Highgrade Plastic Body



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038