DISSOLVED OXYGEN METER 801 & 811 Specification

  • Temperature Range
  • 0C - 50C
  • Feature
  • Highly Efficient
  • Measurement Range
  • 0 to 20 mg/L
  • Capacity
  • Standard
  • Power Source
  • Battery Operated
  • Core Components
  • Sensor Probe, Processor Unit, Display Screen
  • Automation Grade
  • Manual
  • Model No
  • 801 & 811
  • Frequency
  • 50 Hz
  • Voltage
  • 230V AC
  • Accuracy
  • 100 %
  • Equipment Materials
  • High Grade Plastic and Metal
  • Type
  • Portable Dissolved Oxygen Meter
  • Usage
  • Laboratory
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 180mm x 85mm x 60mm
  • Weight
  • 600g
  • Electrode Cable Length
  • 1.5 meters
  • Response Time
  • 30 seconds
  • Calibration
  • Manual/Automatic Dual Option
  • Sensor Type
  • Galvanic Sensor
  • Application
  • Water Quality Testing, Aquaculture, Environmental Monitoring
  • Additional Product Specifications
  • Display Resolution
  • 0.01 mg/L
  • Electrode Life
  • 12 months
  • Power Consumption
  • < 5W
  • Data Output
  • RS232 Serial Port
  • Operating Humidity
  • 85% RH
  • Sample Volume
  • 10 ml
 
 

About DISSOLVED OXYGEN METER 801 & 811

FEATURES

         Highly Stable and Accurate

         3 Digit LCD Display

         DO & Temperature Measurements

 

Digital Dissolved Oxygen Meter - 801 & 811 are available in benchtop models. These instruments are extremely useful for agriculture, soil analysis, fisheries, water quality control in boiler feed water, water works, breweries, water purification plants, chemical and pharmaceutical industries etc.

 

SPECIFICATIONS : -

Model

801

811

Range

DO: 0 - 20 ppm
Temp.: 0 - 60 C

DO: 0 - 20 ppm
-

Resolution

DO: 0.1 ppm
Temp.: 0.1 C

DO: 0.1 ppm
-

Accuracy

DO: 0.1 ppm
Temp.: 0.2 C

DO: 0.1 ppm
-

Stirrer

Available

- 

Temp. Comp.

0 - 50 C (Manual)

Calibration

Manual

Display

3 Digit Seven Segment LED

Power  

230 V AC 10%%, 50 Hz

Dimensions

275 x 135 x 75 mm (L x B x H) (Approx.)

Weight 

3.5 Kg (Approx.)

Accessories

Gold/Silver Amperometric DO Probe, Set of DO Membranes,
Temperature Probe (Model - 801), Stirrer and Magnetic Capsule (Model - 801), Operation Manual and Dust Cover,

Note :  Specifications are subject to change due to continuous improvements.



High Precision Oxygen Measurement

Equipped with a galvanic sensor and a digital display offering 0.01 mg/L resolution, the 801 & 811 meters deliver fast and accurate dissolved oxygen analysis. The manual/automatic dual calibration ensures reliable readings in every use, supporting quality control in aquaculture, labs, and environmental settings.


User-Friendly and Efficient Design

Lightweight at just 600 grams and compact in form, these meters are easily portable. They require a minimum 10 ml sample size and operate on battery or 230V AC power. Highly efficient with power consumption under 5W, these models allow easy, prolonged use in various field or laboratory conditions.


Robust Features for Diverse Applications

Built from high-quality materials, the DISSOLVED OXYGEN METER 801 & 811 function seamlessly across a temperature range of 0C 50C, sustaining up to 85%% RH. With an electrode cable length of 1.5 meters and RS232 serial data output, the meters offer flexible and secure data collection for manufacturers, suppliers, and traders in India.

FAQs of DISSOLVED OXYGEN METER 801 & 811:


Q: How is the DISSOLVED OXYGEN METER 801 & 811 calibrated?

A: These meters offer both manual and automatic dual calibration options, providing flexibility for users to ensure measurement accuracy based on their standard operation procedures or referencing solutions.

Q: What types of environments can I use these oxygen meters in?

A: The 801 & 811 models are suitable for aquaculture, laboratory usage, and environmental monitoring. Their rugged design and broad operating temperature and humidity tolerances allow use in both field and controlled laboratory conditions.

Q: When should the electrode in the oxygen meter be replaced?

A: The electrode has a service life of at least 12 months under typical usage. Replacement is recommended if the response time increases beyond 30 seconds or if calibration becomes difficult.

Q: Where can data from measurements be exported?

A: Measurement data can be exported through the RS232 serial port, allowing easy documentation, analysis, or integration with laboratory information management systems.

Q: What is the minimum sample volume required for accurate measurement?

A: The device requires a minimum sample volume of 10 ml for precise dissolved oxygen readings, making it ideal for testing even small water samples in various scenarios.

Q: How does the meter ensure efficient power usage during operations?

A: With a power consumption of less than 5W, the 801 & 811 meters are highly efficient and suitable for extended fieldwork, operating on standard 230V AC power or batteries.

Q: What are the main benefits of choosing the 801 & 811 models?

A: These meters provide rapid, accurate readings, are easy to operate, transport, and calibrate, and support digital data output for thorough documentationmaking them ideal for professionals involved in water quality testing and monitoring.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ANALYTICAL INSTRUMENTS Category

MICROPROCESSOR PH METER 1012 & 1013

MICROPROCESSOR PH METER 1012 & 1013

Accuracy : 100 %

Type : Microprocessor PH Meter

Model No : 1012 & 1013

Equipment Materials : ABS plastic body

Voltage : 220 V AC

Usage : Laboratory

AUTO KARL FISCHER TITRIMETER 751 & 761

AUTO KARL FISCHER TITRIMETER 751 & 761

Accuracy : 100 %

Type : Automatic Karl Fischer Titrimeter

Model No : 751 & 761

Equipment Materials : Sturdy chemicalresistant body, glass titration vessel

Voltage : 230V

Usage : Laboratory

MICROPROCESSOR DISSOLVED OXYGEN METER 1801

MICROPROCESSOR DISSOLVED OXYGEN METER 1801

Accuracy : 100 %

Type : Microprocessor Dissolved Oxygen Meter

Model No : 1801

Equipment Materials : ABS Plastic

Voltage : 230 V AC 10%

Usage : Laboratory

DIGITAL CONDUCTIVITY METER (HANDHELD) 621

DIGITAL CONDUCTIVITY METER (HANDHELD) 621

Accuracy : 1%

Type : Conductivity Meter

Model No : 621

Equipment Materials : Plastic

Voltage : DC 9V

Usage : Water Quality Testing Laboratory Use



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038