VENTILAION APPARATUS
VENTILAION APPARATUS

VENTILAION APPARATUS

VENTILAION APPARATUS Specification

  • Temperature Range
  • Ambient to 60C
  • Capacity
  • Laboratory scale (as per requirement)
  • Accuracy
  • 1% on measurement
  • Frequency
  • 50 Hz
  • Power Source
  • Electric
  • Feature
  • Variable airflow, Transparent ductwork, Versatile experimentation
  • Voltage
  • 230 V AC
  • Core Components
  • Fan, Duct, Airflow Meter, Control Panel
  • Equipment Materials
  • Stainless Steel and Borosilicate Glass
  • Type
  • Ventilation Apparatus
  • Dimension (L*W*H)
  • 1100 x 600 x 1300 mm
  • Weight
  • Approx. 40 kg
  • Fan Speed Control
  • Variable by control knob
  • Operation Manual
  • Provided with equipment
  • Noise Level
  • 55 dB
  • Duct Diameter
  • 100 mm
  • Air Velocity Range
  • 0.1 to 10 m/s
  • Safety
  • Overload protector for motor/fan
 
 

About VENTILAION APPARATUS

VENTILAION APPARATUS

Demonstrates principle of ventilation in mines, using natural draft, via convection in air, Rectangular, metal box with sliding, glass front and two detachable, cylindrical glass chimneys fitted on top of the box.



Advanced Control & Versatility

Experience unparalleled variable airflow management with this ventilation apparatus. The intuitive control knob adjusts fan speed for precise air velocity, making it ideal for a range of experimental setups. The transparent ductwork allows direct airflow observation, facilitating comprehensive studies in a safe and quiet environmentperfect for educational and research laboratories.


Robust, Safe Construction

Crafted from stainless steel and borosilicate glass, the apparatus combines durability and functionality. The included overload protector safeguards both the fan and motor during extended operation, while a noise output of 55 dB maintains a comfortable working atmosphere. Its laboratory-grade construction ensures reliable performance and ease of maintenance.

FAQs of VENTILAION APPARATUS:


Q: How do I adjust the fan speed on the ventilation apparatus?

A: You can easily adjust the fan speed using the variable control knob located on the control panel. This allows you to select the desired airflow, with velocity ranging between 0.1 and 10 m/s.

Q: What types of experiments can be conducted with this ventilation apparatus?

A: This equipment is suited for laboratory-scale studies such as airflow measurement, duct flow analysis, and ventilation efficiency experiments, accommodating versatile research and educational needs.

Q: When should the overload protector be used?

A: The overload protector automatically activates to safeguard the motor and fan if the system detects an excessive load or abnormal operation, requiring no manual intervention during typical usage.

Q: Where is the apparatus best placed for operation?

A: Place the apparatus on a firm, level laboratory surface with sufficient clearance for ventilation and safe access to all components. Avoid locations with extreme humidity or temperatures beyond its ambient to 60C range.

Q: What is the process for setting up the equipment for the first time?

A: Refer to the provided operation manual for detailed steps. Typically, setup involves assembling the core components, connecting to a 230 V AC power source, and calibrating the airflow meter for accurate measurement.

Q: How does the transparent ductwork benefit the user?

A: The transparent borosilicate glass duct allows clear visualization of airflow patterns and dynamics during experiments, enhancing learning and enabling real-time observation of flow behavior.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PHYSICS LABORATORY EQUIPMENT Category

MECHANICS SET

MECHANICS SET

Model No : Not Available

Usage : Laboratory

Equipment Materials : Metal and Plastic

Feature : Highly Efficient

Core Components : Mechanical Tools

Measurement Range : Not Available

Weather Station

Weather Station

Model No : WS100

Usage : Indoor/Outdoor

Equipment Materials : Metal Plastic

Feature : Weather monitoring

Core Components : Barometer Thermometer Hygrometer

Measurement Range : Temperature Humidity Atmospheric Pressure

ELECTROMAGNET, U-TYPE

ELECTROMAGNET, U-TYPE

Model No : EMUTYPE01

Usage : Educational Industrial Applications

Equipment Materials : Aluminium Copper Iron

Feature : Strong Magnetic Force

Core Components : Magnetic Coil Iron Armature

Optical Bench Set

Optical Bench Set

Model No : OBS001

Usage : Educational settings optical experiments

Equipment Materials : Metal plastic

Feature : Adjustable components for experiment setup

Core Components : Bench lenses holders measurement components

Measurement Range : Varies depending on assembled configuration



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038