Back to top
   Call Me Free Send SMS Send Inquiry
Stainless Steel Cement Autoclaves
Stainless Steel Cement Autoclaves

Stainless Steel Cement Autoclaves

Stainless Steel Cement Autoclaves Specification

  • Type
  • Front loading horizontal autoclave
  • Chamber Size
  • 550 x 350 x 400 mm
  • Chamber Thickness
  • 5 mm stainless steel
  • Outer Size
  • 1000 x 600 x 600 mm (customizable)
  • Door Type
  • Horizontally sliding, manual lock
  • Design Pressure
  • 0.24 MPa
  • Working Pressure
  • 0.22 MPa
  • Design Temperature
  • 139C
  • Heat Uniform
  • 1C distribution
  • Net Weight
  • Approx. 180 kg
  • Recording Parameters
  • Digital display, automatic logging
  • Spraying Mode
  • Automatic 360 circulation
  • Outer Trolley
  • Stainless Steel, removable
  • Inner Trolley
  • Stainless Steel, autoclave compatible
  • Spraying Piping
  • 316L stainless steel, corrosion resistant
  • Sterilizing Temperature
  • 134C (max)
  • Working Temperature
  • 121C or 134C selectable
  • Sterilization Time
  • 099 minutes, adjustable
  • Temperature Scope
  • 100C to 134C
  • Piping System
  • Stainless steel seamless pipes
  • Valves
  • Stainless steel safety and exhaust valves
  • Power Consumption
  • 69 kW, depending on model
 
 

About Stainless Steel Cement Autoclaves

Stainless Steel Cement Autoclaves

We are engaged in manufacturing and exporting a wide range of Cement Autoclaves. These products includes a stainless steel cylinder with a welded heat insulated voer that is confined in a heat insulated metal housing, mounted on a sturdy supporting frame. In order to control the electric heating units, the attached control unit holds in a sensitive pressure regulator, pressure gauze, power switches and pilot lights. In addition to this, to hold specimens above water level in a vertical position and autoclave, laboratory cement autoclave is offered by us with test bar holder and special rack to expose them in the same manner.

Technical specifications:-

  • Inside chamber dimensions are 10.5 cm diameter x 40.5 cm height
  • The device is suitable for operation on 230 V, 50 Hz, single phase A.C. supply.


Precision Construction and Compliance

Built from high-grade 316/304 stainless steel, both the body and door provide exceptional durability and resistance to corrosion. The autoclave is fully compliant with IS:4031, IS:1727, and ASTM standards, ensuring consistent and accurate cement testing results for laboratories and manufacturers.


Advanced Operation and Control

Automatic and manual water supply options, digital recording, and LED/LCD displays deliver ease of use. Adjustable sterilization parameters and a front-loading horizontal design streamline cement sample processing, whilst the 360 automatic spraying circulation system optimizes temperature uniformity within the chamber.

FAQs of Stainless Steel Cement Autoclaves:


Q: How do you operate the Stainless Steel Cement Autoclave for cement testing?

A: To operate, load cement test samples into the inner stainless steel trolley compatible with the autoclave. Select water supply mode (automatic or manual) and adjust parameters on the LED/LCD display. Set desired temperature (100C134C) and sterilization time (099 minutes). After processing, remove samples using the removable outer trolley.

Q: What materials are used in the construction of the autoclave?

A: The autoclave features a body and door made from corrosion-resistant 316/304 stainless steel. The chamber has a polished mirror finish and 5 mm thickness for durability, while seamless stainless steel piping and safety valves ensure reliable operation.

Q: When should you use the autoclaves adjustable sterilization settings?

A: Adjustable temperature and sterilization time are useful for different cement testing protocols. For standard tests, select 121C or 134C working temperature as required; set the timer according to specific cement standard methods (such as IS:4031 or ASTM procedures).

Q: Where is this autoclave suitable for installation and usage?

A: This equipment is ideal for construction material laboratories, cement manufacturing units, and research centers in India, as it meets national and international standards for cement testing and material analysis.

Q: What is the process for maintaining the autoclaves sealing system?

A: Regularly inspect the high temperature-resistant silicon rubber gasket for signs of wear, and replace when necessary. Ensure the horizontally sliding door is properly locked before each run, and check the stainless steel safety and exhaust valves for unobstructed operation.

Q: How does the autoclave benefit cement testing applications?

A: It provides precise temperature control, uniform heating (1C), and reliable logging of test parameters, resulting in accurate, repeatable outcomes. Its robust stainless steel build and compliance with IS and ASTM standards support consistent quality and long-term laboratory use.

Q: Can the outer and inner trolleys be customized for sample sizes?

A: Yes, both the outer removable trolley and the inner autoclave-compatible trolley are made of stainless steel and can be tailored to accommodate different sample dimensions as required by specific laboratory procedures.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in AUTOCLAVES Category

Table Top Autoclaves

Table Top Autoclaves

Sterilizing Temperature : 121C

Working Pressure : 0.22 Mpa

Working Temperature : 105C 134C

Valves : Safety valve, exhaust valve

Chamber Size : 385 x 250 mm

Door Type : Manual single door

Cement Autoclaves

Cement Autoclaves

Sterilizing Temperature : Up to 132C

Working Pressure : 2.1 kg/cm

Working Temperature : Up to 132C

Valves : Pressure and safety release valves fitted

Chamber Size : 200 x 600 mm

Door Type : Hand wheel type locking system

Horizontal Rectangular Autoclaves

Horizontal Rectangular Autoclaves

Sterilizing Temperature : 121C to 134C

Working Pressure : 1.2 Bar

Working Temperature : 121C

Valves : Automated ball valves for inlet & outlet

Chamber Size : 1000 x 600 x 600 mm (customizable)

Door Type : Horizontal sliding/Manual or Automatic

Horizontal Autoclaves

Horizontal Autoclaves

Sterilizing Temperature : 121C standard, up to 134C for advanced cycles

Working Pressure : 1.2 2.2 bar

Working Temperature : Up to 128C continuous

Valves : Driven by pneumatic or electric actuator, SS316

Chamber Size : 1100 x 500 x 500 mm (other sizes on request)

Door Type : Horizontal sliding or radial arm locking door



SINGHLA SCIENTIFIC INDUSTRIES
GST : 06ACOPS0805K1ZD
No-5309/27, Punjabi Mohalla, Ambala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)