Back to top
Send SMS Send Inquiry
PH/MV/CONDUCTIVITY/TDS/SALT/TEMP 7200
PH/MV/CONDUCTIVITY/TDS/SALT/TEMP 7200

PH/MV/CONDUCTIVITY/TDS/SALT/TEMP 7200

PH/MV/CONDUCTIVITY/TDS/SALT/TEMP 7200 Specification

  • Accuracy
  • 100 %
  • Power Source
  • Electric
  • Feature
  • Highly Efficient
  • Capacity
  • Not Specified
  • Frequency
  • 50/60 Hz
  • Voltage
  • 230 V AC
  • Model No
  • 7200
  • Core Components
  • Microprocessor Controller
  • Automation Grade
  • Automatic
  • Temperature Range
  • 0-100C
  • Measurement Range
  • PH: 0.00-14.00; MV: 1999 mV; Conductivity: 0-200 mS/cm; TDS: 0-100 g/L; Salt: 0-100 ppt; Temp: 0-100C
  • Equipment Materials
  • ABS Plastic
  • Type
  • PH/ORP/Conductivity/TDS/Salt/Temperature Meter
  • Usage
  • Laboratory
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 210 x 185 x 60 mm
  • Weight
  • 400 g
 
 

About PH/MV/CONDUCTIVITY/TDS/SALT/TEMP 7200

FEATURES

 

         Microprocessor Based

         IP-57 Water Proofing

         Floats on Water

         Large LCD Display

         Automatic Temperature Compensation (ATC)

         Data Hold, Max/Min and C/ F switchable

         Low Battery and Consumption Indicator

         Auto Power-Off after 10 minutes

         Replaceable Sensor

 

pH/Conductivity/TDS/Salt/Temp Waterproof Tester 7200 is a microprocessor based tester used to determine pH, mV, Temperature, Conductivity, TDS and Salts in a liquid. This tester has wide applications in agriculture, anti-freeze recycling, aquarium, boiler, chemical industry, cooling tower, drinking water, fish farming, food industry, garden husbandry, hydroponics, laboratory usage, plating industry, swimming pool & spa, water treatment etc.

It has rugged design for field use. It floats on water. It has Automatic Temperature Compensation (ATC) and is degree C/F switchable. It displays Maximum/Minimum value and data hold on large LCD display. It has low battery and consumption indicator along with auto shut off after 10 minutes of non use.

 

SPECIFICATIONS : -

Display

Large LCD to display respective parameters,
Battery level, ATC & Temperature

Range

pH: -2 - 16.00
TDS: 0 - 1300 ppm
1.30 - 13.00 ppt
Cond: 0 - 2000 S
2.00 - 20.00 mS

mV: -1000 - 1000 mV
Salt: 0 - 1000 ppm
1.00 - 12.00 ppt
Temp: 0 - 90.0 C
32 - 194.0 F

Resolution

pH: 0.01 pH, mV: 1 mV, TDS: 1 ppm/0.01 ppt,
Cond.: 1 S/0.01 mS, Temp.: 0.1 C/F,
Salt: 1 ppm/0.01 ppt

Accuracy

pH: 0.01 +1 Digit, mV: 2 +1 Digit,
TDS/Cond/Salt: 2%% of F.S., Temp: 0.2 C +1 Digit

Automatic Temperature

Automatic Temperature Compensation (ATC)
with temperature display

Temperature Coefficient

2%% per C

Sensor

User Replaceable

Water Proof

As per IP 57 water proofing standard

Calibration

Calibration pH: 4.00, 7.00 and 10.01,
Cond.: 0 S, 1413 S, 12.88 mS

Power

DC 1.5 V x 4 battery (UM-4/AAA)
Auto power off after 10 minutes

Dimensions
(L x B x H)

Meter: 195 x 40 x 36 mm (Approx.)
Kit: 230 x 205 x 50 mm (Approx.)

Weight

Meter: 135 g with battery, Kit: 780 g

Others Features

Auto Power-off after 10 minutes, Hold function to freeze reading, Push button calibration, Water-proof IP-57, Temperature coefficient - 2%% per C, Self-Diagnostics message for low battery

Accessories

Standard Calibration Solution (50 ml), Battery, Lanyard, Operation Manual and Carrying Case

Note :  Specifications are subject to change due to continuous improvements.



Advanced Multi-Parameter Measurement

The 7200 model seamlessly integrates pH, mV, conductivity, TDS, salt, and temperature measurements, providing comprehensive solution analysis with a single compact device. Its high-resolution sensors and automatic/manual temperature compensation ensure consistently reliable results, making it indispensable for laboratories that demand efficiency and precision.


User-Friendly Design and Display

Equipped with a large backlit LCD and a multiline display, the instrument allows users to view multiple parameters simultaneously. The ergonomic setup, including an electrode stand and a robust carrying case, simplifies day-to-day operations and transportation, ensuring ease of use even in busy laboratory settings.


Versatile Calibration and Data Management

The instrument supports one to five-point calibration for pH, enhancing measurement reliability across a range of samples. It also features storage for up to 99 data sets, enabling efficient tracking and review of analytical results. This versatility is complemented by a straightforward calibration process guided by supplied buffer solutions.

FAQs of PH/MV/CONDUCTIVITY/TDS/SALT/TEMP 7200:


Q: How do I calibrate the PH/MV/CONDUCTIVITY/TDS/SALT/TEMP 7200 for pH measurements?

A: The 7200 allows one to five-point calibration for pH measurements using supplied buffer solutions. Simply follow the on-screen instructions to immerse the electrode in each buffer solution sequentially for accurate calibration.

Q: What types of samples can this instrument analyze and where is it best used?

A: This instrument is suitable for aqueous sample analysis in laboratory environments, including water quality testing, research applications, and industrial labs. Its broad measurement ranges and robust design make it a practical choice for various sectors in India.

Q: When should the electrode be replaced or maintained for optimal performance?

A: Regular maintenance, such as rinsing and proper storage of the combined pH/conductivity electrode, should be performed after each use. Replacement is recommended when readings become unstable or calibration cannot be achieved despite cleaning.

Q: Where does the stored data go, and how can I access previous measurements?

A: The device internally stores up to 99 sets of measurement data. You can recall previous measurements easily through the devices menu on the large backlit LCD display for further analysis or documentation.

Q: What is the process for using temperature compensation during measurements?

A: The 7200 offers both automatic and manual temperature compensation. For automatic compensation, ensure the temperature probe is connected; the instrument will adjust readings accordingly. Manual input is also available if temperature data is measured externally.

Q: What benefits does the IP54 protection standard provide in laboratory settings?

A: IP54-rated protection guards the device against dust and splashing liquids, ensuring reliable operation and extending equipment lifeeven in humid or spill-prone environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ANALYTICAL INSTRUMENTS Category

DIGITAL TURBIDITY METER 335, 331 & 341

DIGITAL TURBIDITY METER 335, 331 & 341

Accuracy : 100 %

Feature : Highly Efficient

Power Source : Electric

Usage : Laboratory

Dimension (L*W*H) : 245 x 205 x 100 mm

Equipment Materials : ABS Plastic Body

DIGITAL CONDUCTIVITY TDS/METER 641

DIGITAL CONDUCTIVITY TDS/METER 641

Accuracy : 100 %

Feature : Highly Efficient

Power Source : AC Mains

Usage : Laboratory

Dimension (L*W*H) : 240 x 175 x 75 mm

Equipment Materials : Plastic Body

DOUBLE BEAM SPECTROPHOTOMETER 1372

DOUBLE BEAM SPECTROPHOTOMETER 1372

Accuracy : 100 %

Feature : Highly Efficient

Power Source : Electric

Usage : Laboratory

Dimension (L*W*H) : 625 x 430 x 210 mm

Equipment Materials : HighQuality Metal & Plastic Housing

DIGITAL PH, CONDUCTIVITY & TEMPERATURE METER 181

DIGITAL PH, CONDUCTIVITY & TEMPERATURE METER 181

Accuracy : 100 %

Feature : Highly Efficient

Power Source : 230V AC

Usage : Laboratory

Dimension (L*W*H) : 220 x 180 x 80 mm

Equipment Materials : HighGrade Plastic Housing



SINGHLA SCIENTIFIC INDUSTRIES
GST : 06ACOPS0805K1ZD
No-5309/27, Punjabi Mohalla, Ambala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038