Back to top
Send SMS Send Inquiry
MICROPROCESSOR SPECTROPHOTOMETER 2305
MICROPROCESSOR SPECTROPHOTOMETER 2305

MICROPROCESSOR SPECTROPHOTOMETER 2305

MICROPROCESSOR SPECTROPHOTOMETER 2305 Specification

  • Feature
  • Highly Efficient
  • Measurement Range
  • 320 nm - 1100 nm
  • Frequency
  • 50 Hz
  • Automation Grade
  • Semi-automatic
  • Voltage
  • 220 V
  • Power Source
  • Electric (220 V AC)
  • Model No
  • 2305
  • Capacity
  • 1000 ml
  • Core Components
  • Optical System, Microprocessor, Display
  • Temperature Range
  • 0C to 100C
  • Accuracy
  • 100 %
  • Equipment Materials
  • ABS Plastic & Metal
  • Type
  • Microprocessor Spectrophotometer
  • Usage
  • Laboratory
  • Display Type
  • LCD Digital Display
  • Dimension (L*W*H)
  • 475 x 350 x 190 mm
  • Weight
  • 15 kg
 
 

About MICROPROCESSOR SPECTROPHOTOMETER 2305

FEATURES

·         Microprocessor Based

·         4 Digit Seven Segment Bright Red LED Display

·         Easy to Use, Press one button for easyswitching of %%T, Abs., Conc. modes

·         Auto Zero and Blank

·         Printer Attachment Facility

·         PC Connectivity through USB

·         Large Sample Compartment, can accommodate5-100 mm path length cuvettes with optionalholders.


Microprocessor Spectrophotometer is a solid state microcontroller based instrument designed for quick and accurate spectrophotometric analysis of any concentration. It operates at a wavelength range of 325 nm to 1000 nm. The output is available on a 4 Digit seven segment bright red LED display in terms of %%Transmission (%%T), Absorbance (Abs.), Concentration (Conc.) and Kfactor. The instrument uses the latest microprocessor technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility.

This is the most economical, reliable, rugged and accurate instrument. The system has 4 soft touch membrane type keys for ease of operation. It has a 'Mode' key for easy switching of various operating modes. Facility for automatic setting of zero / blank is provided.

Provision has also been made for attachment of any dot matrix printer using centronics interface and PC connectivity through USB port.

System has a 4-Position rapid cuvette changer (Test Tube Holder) selector.

 

SPECIFICATIONS : -

Optics

Single Beam, Grating 1200 lines/mm

Wavelength
Range

325 - 1000 nm

Wavelength
Resolution

2 nm

Spectral
Bandwidth

4 nm

Wavelength
Accuracy

± 2 nm

Photometric
Accuracy

± 0.5 %%T

Photometric
Repeatability

0.3 %%T

Photometric
Range

0 - 200 %%T, - 0.3 to 3A, 0 - 9999 Conc.

Photometric
Mode

%%Transmission, Absorbance, Concentration and KFactor

Stray Light

< 0.3 %%T

Stability

± 0.002 A/h @ 500 nm

Display

4 Digit 7-Segment Bright Red LED

Detector

Silicon Photodiode

Sample
Compartment

Standard 4-Position 10 mm path-length cuvette holder.
Accomodates upto 100 mm path-length cuvette with optional holder

Output

USB port for PC Connectivity, Parallel Port for Dot Matirx Printer

Light Source

Tungsten Halogen Lamp

Power

230 V ±10%% AC, 50 Hz

Dimensions
(L x B x H)

420 x 280 x 180 mm (Approx.)

Weight

8 Kg (Approx.)

Accessories

Glass Cuvettes - A set of 4, Mains Lead, Black Block,
Operation Manual and Dust Cover

Note :  Specifications are subject to change due to continuous improvements.




Advanced Optical and Data Capabilities

Equipped with a silicon photodiode detector and automatic switching between tungsten and deuterium lamps, the 2305 delivers high precision measurements across a wavelength range of 3201100 nm. Its 0.1 nm display resolution and 2 nm wavelength accuracy make it suitable for diverse analytical tasks. Lab professionals benefit from its reliable spectroscopic data output via RS232 interface, supporting streamlined data management and connectivity.


User-Friendly Design and Versatility

The spectrophotometer features a semi-automatic operation and an intuitive digital LCD display. With a 4-position cuvette holder, users can conduct multiple assays with either glass or quartz cuvettes (provided). Its ergonomic ABS plastic and metal frame enhance durability and ease of maintenance, while the temperature range of 0C to 100C adds versatility to different sample types and experimental needs.

FAQs of MICROPROCESSOR SPECTROPHOTOMETER 2305:


Q: How does the Microprocessor Spectrophotometer 2305 ensure measurement accuracy?

A: The Model 2305 incorporates a highly stable optical system with a silicon photodiode detector, wavelength accuracy of 2 nm, and photometric accuracy of 0.5%% T. Automatic lamp switching between tungsten and deuterium sources further minimizes manual errors and maintains consistent accuracy across its measurement range.

Q: What is the process for using the 4-position cuvette holder included with the 2305?

A: Users can insert up to four cuvettes (two glass, two quartz included) into the holder. The device allows for swift selection and measurement of each cuvette, streamlining workflows that require parallel or comparative analysis of multiple samples.

Q: When is it beneficial to utilize both glass and quartz cuvettes with this spectrophotometer?

A: Quartz cuvettes are recommended for measurements in the UV range (below 350 nm), while glass cuvettes suffice for visible spectrum analysis. The inclusion of both types allows users to perform a broader range of assays without additional accessories.

Q: Where can data outputs from the 2305 be exported for analysis or record-keeping?

A: Data obtained from the spectrophotometer can be exported through its RS232 interface, enabling easy integration with laboratory computers or external storage devices for efficient documentation and further data analysis.

Q: What are the main benefits of using the Microprocessor Spectrophotometer 2305 in a laboratory setting?

A: Benefits include high measurement accuracy, broad wavelength range, user-friendly semi-automatic operation, durable construction, and compatibility with both glass and quartz cuvettes. These features collectively support reliable, repeatable results for varied laboratory applications.

Q: How does automatic light source switching improve laboratory workflow with the 2305?

A: Automatic switching between tungsten and deuterium lamps optimizes light frequency for sample analysis, eliminating manual adjustments. This enhances efficiency and reduces potential errors, particularly during extensive or sequential spectroscopic measurements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ANALYTICAL INSTRUMENTS Category

DIGITAL PHOTO COLORIMETER 312, 313, 321 & 322

DIGITAL PHOTO COLORIMETER 312, 313, 321 & 322

Automation Grade : SemiAutomatic

Usage : Laboratory

Equipment Materials : ABS Plastic, Metal

Type : Digital Photo Colorimeter

Feature : Highly Efficient

Weight : 3.5 Kg (Approx.)

DIGITAL UV-VIS SPECTROPHOTOMETER 371

DIGITAL UV-VIS SPECTROPHOTOMETER 371

Automation Grade : SemiAutomatic

Usage : Laboratory

Equipment Materials : Metal and plastic housing

Type : UVVIS Spectrophotometer

Feature : Highly Efficient

Weight : Approx. 12 kg

MICROPROCESSOR COLONY COUNTER 1361, 1362 & 1363

MICROPROCESSOR COLONY COUNTER 1361, 1362 & 1363

Automation Grade : Semi Automatic

Usage : Laboratory

Equipment Materials : Mild Steel Powder Coated

Type : Digital Microprocessor Colony Counter

Feature : Highly Efficient

Weight : 5 kg (approx)

MICROPROCESSOR PH-EC METER 1611

MICROPROCESSOR PH-EC METER 1611

Automation Grade : SemiAutomatic

Usage : Laboratory

Equipment Materials : Highgrade Plastic Body

Type : PHEC Meter

Feature : Highly Efficient

Weight : 3.0 Kg (approx.)



SINGHLA SCIENTIFIC INDUSTRIES
GST : 06ACOPS0805K1ZD
No-5309/27, Punjabi Mohalla, Ambala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038