Flouroscent Microscopes Specification

  • Automation Grade
  • Manual
  • Model No
  • FM-2000
  • Capacity
  • Not Specified
  • Temperature Range
  • Not Required
  • Voltage
  • 220 V
  • Feature
  • Highly Efficient
  • Accuracy
  • 100 %
  • Measurement Range
  • Visible Fluorescent Spectrum
  • Power Source
  • Electric
  • Core Components
  • Optical Head, Fluorescent Light Source, Objective Lenses, Filters
  • Equipment Materials
  • Metal Body, Optical Glass Components
  • Type
  • Fluorescent Microscope
  • Usage
  • Laboratory
  • Display Type
  • Optical
  • Dimension (L*W*H)
  • 390 x 285 x 425 mm
  • Weight
  • Approx. 6-10 Kg
 
 

About Flouroscent Microscopes

Flouroscent Microscopes

Our trinocular fluorescence microscope is highly efficient microscope, which comes with diopter adjustment ring on ocular tube & with adjustment iris diaphragm and swing out auxiliary lens. It works with great accuracy in its specified field of operation. This cost effective microscope is available with following specifications & added advantages.

Specification: -
Mechanical Body

ü      Co-axial focussing controls with large knobs, pre focusing lever & tension adjustment ring.

ü      Reverse angle quadruple nosepiece.

ü      Mechanical stage is 140 mmx160 mm and having low positioned co-axial controls.

ü      The illuminator incorporates 6V/20W halogen bulb and has adjustable iris diaphragm.

Trinocular Head

ü      Binocular siedentopf head ratable at 360 degree inclined at 30 degree.

ü      Light path selector lever to direct either full light to observation head or 80%% to vertical phototube and 20%% to observation tube.

ü      Diopter adjustment ring on occular tube.

ü      Interpupiliary distance from 55 mm to 75 mm.

Sub-Stage Condenser

ü      The Abbe condenser has N.A 1.25 with adjustment iris diaphragm and swing out auxiliary lens.

Eyepiece

ü      Wide field 10x (Paired)

Objectives

ü      4X FL (UV Pass, Achromatic)

ü      10X FL (UV Pass, Achromatic)

ü      40XR-FL (UV Pass Achromatic)

ü      100 XR-FL (UV Pass Achromatic)

Filters

ü      Board -band filter set Blue & Green, excitation 420-485 nm dichroic mirror as a special filter.

Epilluminator

ü      High intensity 100 w Mercury Vapour Lamp with power supply

ü      Ground filter

ü      6V/30W halogen tungsten bulb

ü      (Spare) Styrofoam moulded pack



Precision Imaging for Advanced Laboratory Applications

Designed for laboratories and medical facilities, the FM-2000 Fluorescent Microscope offers high accuracy and flexibility in a robust, metal-body construction. Ideal for research in cell biology and pathology, its wide magnification range and reliable LED fluorescent illumination deliver crisp, detailed images essential for critical analyses. The mechanical double-layer stage and ergonomic focusing mechanisms make it user-friendly for frequent, intensive usage.


Achromatic Objective Lenses and Efficient Illumination

The FM-2000 utilizes achromatic objective lenses that minimize color aberrations, ensuring sharp image quality at every magnification level. Its LED fluorescent lamp supports extended observation sessions while reducing heat and energy consumption. The 3-position filter turret and widefield eyepieces enhance versatility, allowing quick adaptation to various sample types and staining protocols.

FAQs of Flouroscent Microscopes:


Q: How do you operate the FM-2000 Fluorescent Microscope for cell biology research?

A: Begin by preparing your specimen on the mechanical double-layer stage. Switch on the LED fluorescent lamp to illuminate the sample. Use coarse and fine adjustment knobs to focus the image while toggling between magnifications (40x to 1000x) and switching objective lenses. The 3-position turret holds filters to adjust fluorescence based on staining protocols.

Q: What benefits does the achromatic objective lens provide in this microscope?

A: Achromatic objective lenses significantly reduce chromatic aberration, resulting in sharp, true-color images across the magnification range. This is crucial in medical research and pathology, where accurate visualization supports reliable diagnosis.

Q: When should you use the fluorescent mode in the FM-2000 microscope?

A: Fluorescent mode should be used when working with specimens stained with fluorescent markers or dyes, such as in cell biology or pathology analyses. This enhances contrast and detail, enabling the identification of specific cellular components or pathogens.

Q: Where is the FM-2000 microscope most commonly used?

A: This microscope is primarily utilized in laboratories, hospitals, and research institutes engaged in medical research, cell biology, and pathology. Its CE-certified design meets safety standards expected in professional environments.

Q: What process does the 3-position filter turret support during observation?

A: The filter turret allows swift switching between different fluorescence filters, adapting the observation to diverse dyes and stains and optimizing image clarity throughout various experimental protocols.

Q: How does CE safety compliance benefit users of this microscope?

A: CE certification assures that the FM-2000 meets high safety and performance standards. Laboratory personnel can operate it confidently, knowing it adheres to stringent European regulations for electrical safety and functionality.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in MICROSCOPES Category

Advanced Research microscopes

Advanced Research microscopes

Feature : Advanced precision for researchlevel analysis

Equipment Materials : Metal Plastic

Automation Grade : Manual

Usage : Laboratory and research

Type : Binocular Research Microscope

Core Components : Optical Lens Light Source

Standard Achromatic Objectives

Standard Achromatic Objectives

Feature : Standard achromatic corrections for chromatic aberration and spherical aberration

Equipment Materials : Glass and metal

Automation Grade : Manual

Usage : Microscopy applications

Type : Achromatic Objectives

Core Components : Optical lenses

Junior Medical Microscope

Junior Medical Microscope

Feature : Ideal for basic medical and educational use

Equipment Materials : Metal and glass

Automation Grade : Manual

Usage : Medical and educational purposes

Type : Medical Microscope

Core Components : Optical lens stage focus mechanisms

Research Co-Axial Microscopes

Research Co-Axial Microscopes

Feature : Highly Efficient

Equipment Materials : Metal Body with Optical Components

Automation Grade : Manual

Usage : Laboratory

Type : Research Microscope



SINGHLA SCIENTIFIC INDUSTRIES
GST : 06ACOPS0805K1ZD
No-5309/27, Punjabi Mohalla, Ambala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038