Back to top
Send SMS Send Inquiry
B.o.d. Incubator
B.o.d. Incubator

B.o.d. Incubator

B.o.d. Incubator Specification

  • Core Components
  • Compressor, Microprocessor Controller, Heater
  • Voltage
  • 220 V AC
  • Frequency
  • 50 Hz
  • Temperature Range
  • 5C to 60C
  • Automation Grade
  • Automatic
  • Feature
  • Highly Efficient
  • Capacity
  • 250 L
  • Accuracy
  • 100 %
  • Power Source
  • Electric
  • Measurement Range
  • 5C to 60C
  • Model No
  • BOD-250
  • Equipment Materials
  • Stainless Steel Inner Chamber, Powder Coated Outer Body
  • Type
  • B.O.D. Incubator
  • Usage
  • Laboratory
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 55 cm x 55 cm x 90 cm
  • Weight
  • 75 kg
  • Chamber Illumination
  • Provided
  • Door Type
  • Double Walled with Insulated Glass Window
  • Cooling System
  • Hermetically Sealed Compressor
  • Power Consumption
  • 900 W
  • Safety Features
  • Over Temperature Alarm, Fuse Protection
  • Shelves Material
  • Stainless Steel
  • Temperature Control
  • Digital PID Controller
  • No. of Shelves
  • 3
 
 

About B.o.d. Incubator

B.O.D Incubator are suitable for preservation of vaccines, insulin, lever extracts, chemicals etc. and to make biochemical oxygen demand determination.

Construction : The low temperature incubator is made of double walled M.S sheet finished with epoxy based powder coated paint, inner chamber is made of highly polished stainless steel / anodized aluminium. Two doors are provided. Inner door is made of transparent acrylic for inspecting specimens outer door is insulated and is fitted with magnetic tape with lock and key. Temperature range from 5°C to 50°C with an accuracy of +1°C provided with two air circulating fans, high performance compressor, cooling coils, heating elements. Digital temperature control and display is also fitted with a door operated illumination and a caster wheel for easy mobility. Model No. SSI/93.

SSI/93/01

Cu. FT. : 6.1
Height mm : 825
Width mm : 505
Depth mm : 415
Inner chamber : Aluminium

SSI/93/02

Cu. FT. : 6.1
Height mm : 825
Width mm : 505
Depth mm : 415
Inner chamber : S.S

SSI/93/03

Cu. FT. : 8
Height mm : 850
Width mm : 600
Depth mm : 500
Inner chamber : Aluminium

SSI/93/04

Cu. FT. : 8
Height mm : 850
Width mm : 600
Depth mm : 500
Inner chamber : S.S

SSI/93/05

Cu. FT. : 10
Height mm : 880
Width mm : 550
Depth mm : 550
Inner chamber : Aluminium

SSI/93/06

Cu. FT. : 10
Height mm : 880
Width mm : 550
Depth mm : 550
Inner chamber : S.S.

SSI/93/07

Cu. FT. : 12
Height mm : 900
Width mm : 650
Depth mm : 580
Inner chamber : Aluminium

SSI/93/08

Cu. FT. : 12
Height mm : 900
Width mm : 650
Depth mm : 580
Inner chamber : S.S 

B.O.D. Incubator provided with 304 grade stainless steel outer body & digital temperature controller & display. Model No. SSI/93-A

SSI/93-A/01

Cu. FT. : 6.1
Height mm : 825
Width mm : 505
Depth mm : 415

SSI/93-A/02

Cu. FT. : 8
Height mm : 850
Width mm : 600
Depth mm : 500

SSI/93-A/03

Cu. FT. : 10
Height mm : 880
Width mm : 550
Depth mm : 550

SSI/93-A/04

Cu. FT. : 12
Height mm : 900
Width mm : 650
Depth mm : 580

B.O.D. Incubator provided with P.I.D. Controller instead of electronic digital Temperature cum controller at an extra cost. Model No. SSI/93-B

B.O.D. Incubator provided with P.I.D. Controller instend of digital temperature controller and Rs. 232 / Rs. 485 socket for computer attachment you can control the B.O.D through computer. Model No. SSI/93-C



Precise Temperature Regulation

The B.O.D. Incubators advanced digital PID controller guarantees highly accurate temperature control within the 5C to 60C range. The hermetically sealed compressor system ensures uniform cooling, while the chambers stainless steel construction promotes consistent thermal performance. This reliability is essential for sensitive laboratory processes.


Enhanced Observation and Usability

Designed with a double-walled door featuring an insulated glass window, the incubator allows safe monitoring of specimens without temperature disruption. Internal illumination of the chamber further improves ease of observation, making it convenient for users to check progress without opening the door frequently.


Safety and Efficiency Features

User safety is prioritized through features like an over-temperature alarm and fuse protection. Stainless steel shelves offer hygienic storage, and a powder-coated outer body ensures durability. The automatic operation minimizes human oversight, while the digital display facilitates real-time monitoring of operating parameters.

FAQs of B.o.d. Incubator:


Q: How does the B.O.D. Incubator maintain precise temperature control?

A: The incubator uses a digital PID controller and a hermetically sealed compressor system to maintain stable temperatures in the 5C to 60C range. This ensures accurate and consistent conditions crucial for sensitive laboratory processes.

Q: What are the main benefits of the double-walled door with insulated glass window?

A: The double-walled door, equipped with an insulated glass window, allows users to observe specimens without opening the chamber, thus preserving internal conditions and improving specimen safety. This design also helps maintain thermal efficiency.

Q: When is it recommended to use the over-temperature alarm and safety features?

A: The over-temperature alarm and fuse protection are engaged automatically whenever temperature thresholds are exceeded or electrical anomalies occur. These features safeguard stored samples and the equipment itself during unexpected conditions.

Q: Where can the B.O.D. Incubator be utilized?

A: This model is suitable for various laboratory settings across research facilities, universities, pharmaceutical companies, and industrial labs throughout India. Its robust design supports microbiological, environmental, and biochemical studies.

Q: What is the process for cleaning and maintaining the B.O.D. Incubator?

A: Routine maintenance includes wiping stainless steel shelves and chamber surfaces with appropriate disinfectants. The powder-coated outer body can be cleaned with a damp cloth. Regular calibration of the PID controller and checking the fuse improves longevity and performance.

Q: How does the digital display assist in operation?

A: The incubators digital display offers real-time readings of the chambers temperature and controller settings, providing users with immediate feedback and allowing precise adjustments as needed during experiments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in SCIENTIFIC & LABORATORY RESEARCH APPARATUS Category

Incubator shaker

Incubator shaker

Voltage : 220240V

Temperature Range : 5C to 60C

Frequency : 50 Hz

Equipment Materials : Stainless Steel Glass

Feature : Temperature Control Shaking Function

Type : Incubator Shaker

MUFFLE FURNACE

MUFFLE FURNACE

Voltage : 220240 V AC

Temperature Range : Up to 1200C

Frequency : 50 Hz

Equipment Materials : Mild Steel Outer, Ceramic Chamber

Feature : Rapid Heating, High Accuracy Temperature Control

Type : Lab Furnace

Chiller Refrigerated Circulater Model No. SSI/71

Chiller Refrigerated Circulater Model No. SSI/71

Voltage : 220240 V

Temperature Range : 20C to +100C

Frequency : 50 Hz

Equipment Materials : Corrosion resistant Stainless Steel

Feature : Highly Efficient

Type : Chiller Refrigerated Circulater

Rotary Vacuum Evaporator Cold Trap Condenser Model No. SSI/68

Rotary Vacuum Evaporator Cold Trap Condenser Model No. SSI/68

Voltage : 220 V AC

Temperature Range : 40C to +100C

Frequency : 50 Hz

Equipment Materials : Borosilicate Glass, SS304 Stainless Steel

Feature : Highly Efficient

Type : Rotary Vacuum Evaporator Cold Trap Condenser



M/S SINGHLA SCIENTIFIC INDUSTRIES
GST : 06AOXPS4632P1ZW
5309/27, PUNJABI MOHALLA, Punjabi MohallaAmbala Cantt - 133001, Haryana, India
Phone :07971191038
Mr Devender Singhla (Chief Executive)
Mobile :07971191038