About AUTOCLAVE VERTICAL TRIPLE WALLED HIGH PRESSURE FOR DRY STERLIZATION
APPLICATIONS : -
"SSI Triple walled High Pressure Autoclave are used where Dry Sterilization is required.
Triple walled High Pressure Autoclave are most ideal for critical applications requiring assured and reliable total destruction of all living micro- organisms
It is used for sterilizing of surgical instruments, dressing material, linen, rubber, plastic material, injection liquids by means of steam under pressure of 15 to 20 psi. (adjustable).
SALIENT FEATURES & CONSTRUCTION : -
Used for Dry Sterilization
Steam Jacket & Outer wall made of S. S. 304 Grade
Water Level Indicator
Lid Closing by Radial Locking System
Sealing of Lid by Neoprene Rubber Gasket
Lid is fitted with Pressure Gauge, Spring Loaded Safety Valve.
Operating range from 15psi to 20psi pressure
Hydraulically Tested up to 40 psi.
Sterilizing Temperature up to 1340C
Tested up to 2.5 times of required Pressure
Voltage: 220 Volts AC (50 Hz)
Advanced Triple-Wall Construction for Optimal EfficiencyThe autoclaves triple-walled design utilizes high-grade stainless steel (SS 304/316) with mineral wool insulation. This ensures exceptional heat retention, minimizes energy consumption, and maintains consistent sterilization cycles, making it ideal for intensive laboratory environments.
Reliable and Safe Sterilization ProcessFeaturing an adjustable sterilization cycle (060 minutes) and a maximum pressure of 2.2 kg/cm (30 psi), the autoclave ensures precise, controlled sterilization. Multiple safety mechanisms, including automatic pressure cut-off and a pressure release valve, are incorporated for user protection.
Convenient Operation and MaintenanceEase of use is enhanced by features like a radial arm/foot lever lid lock, built-in water level indicator, and a draining system. The immersion heater is easily replaceable, and optional accessoriessuch as baskets, perforated trays, or a printer interfaceexpand functionality.
FAQs of AUTOCLAVE VERTICAL TRIPLE WALLED HIGH PRESSURE FOR DRY STERLIZATION:
Q: How do you adjust the sterilization cycle on the autoclave?
A: You can easily set the sterilization cycle on the autoclave from 0 to 60 minutes using the built-in adjustable timer, allowing flexibility depending on the specific items being sterilized.
Q: What types of materials can be sterilized with this autoclave?
A: This unit is ideal for sterilizing media, glassware, laboratory instruments, and other heat-resistant items commonly used in laboratory settings.
Q: When should the gasket be replaced, and what materials are used?
A: The gasket should be inspected regularly for wear or damage and replaced as needed. Autoclaves of this type use durable synthetic rubber or silicone gaskets for optimal sealing and longevity.
Q: Where should this vertical autoclave be installed?
A: This model is designed to be installed on the floor, ideally in a well-ventilated laboratory area close to a reliable power source (220 V AC) and a water supply for efficient operation.
Q: What safety features are included in the autoclave?
A: The autoclave is equipped with automatic pressure cut-off, a pressure release valve, a secure lid locking mechanism, and a water level indicator to ensure safe operation during every cycle.
Q: How is water removed from the chamber after sterilization?
A: A built-in draining system allows for rapid and convenient removal of water after each sterilization cycle, simplifying maintenance and ensuring hygienic conditions.
Q: What are the benefits of the mineral wool insulation in the autoclave?
A: Mineral wool insulation between the triple walls maximizes thermal efficiency by retaining heat, minimizing energy loss, and supporting stable temperature and pressure during sterilization.